DEVELOPMENT AND PERFORMANCE MEASUREMENT OF ROOM AIR-CONDITIONER SUITABLE FOR HOUSE IN COLD REGION

Recently, performance of insulation and air tightness for residential house has been improved in cold region. Therefore, heating load remains at low level through most of heating period. Inverter controlled heat pump is effective appliance to improve efficiency on partial load condition, but it is pointed out that COP operated in low load less than 1kW is not high due to on-off operation. To solve these problems, we make a prototype room airconditioner with inverter-controlled dual compressor which is tuned to low heating load in low outside temperature. We measure COP in various conditions, and conduct the field test to clarify whether prototype room air-conditioner can provide excellent COP in low load. Measured COP on field test is 2.6.

Download

Publication type Conf Proceedings Paper

Publication date 23 September 2011

Authors T. Nogawa, K. Shimizu, M. Ishikawa, I. Hongo

Keywords room air-conditioner, dual compressor, partial load efficiency, field tes