Chemical stability of low-GWP refrigerants with polyol ester (POE) lubricants for high temperature heat pumps

High-temperature heat pumps (HTHPs) can play a significant role in reducing the internal waste heat and replace fossil fuel and electrically driven boilers in different industrial heat treatment and drying processes. The choice of low Global Warming Potential (GWP), zero Ozone Depletion Potential (ODP) and low trifluoroacetic acid yield (TFA) refrigerant for high temperature applications is of highest importance. Only chemically stable refrigerants can ensure long lifetime, safety and steady operation. The novelty of this work is the comparison of lab-controlled chemical stability tests of hydrochlorofluoroolefins (HCFOs) and hydrofluoroolefins (HFOs) alternatives in stainless steel gas reactors using latest ASHRAE guideline 38-2023 at high temperatures up to 150 ºC and high pressures up to 31 bar for 21 days in combination with moisture and polyolester (POE) lubricants as well as in a pilot-scale HTHP installation, against the refrigerant samples from real industrial installations. The refrigerant decomposition products were analysed using Thermo Scientific Trace 1310 Gas Chromatograph with a thermal conductivity detector (TCD) and flame-ionization detector (FID) and compared with AHRI 700-2024 results. The results showed that both HCFO and HFO refrigerants undergo different polymerization processes in the presence of POE lubricants; water; or a mixture of POE lubricants and water. In contrast, the control refrigerant samples (with no water or oil contact) showed very little reactivity after 21-day tests but highly elevated water levels. Highly elevated water levels were found even in samples from real installations confirming that water is one of the degradation by-products. This study demonstrates that both HFO and HCFO refrigerants can be highly sensitive to POE lubricant composition, particularly to a high fraction of branched dipenta-esters, which are commonly selected for high-temperature applications. Key future work includes further Fourier Transform Infrared (FTIR) spectroscopy analysis of obtained polymers and degraded POE lubricants.

Download

Publication type Conf Proceedings Paper

Publication date 26 May 2026

Authors Monika Ignatowicz, Saman Nimali Gunasekara, Yixiu Dong, Björn Palm, Rahmatollah Khodabandeh, Mats Johansson, Ruzhu Wang, Aanandsundar Arumugam, Oronzio Manca

Keywords Refrigerant; Lubricant;, High Temperature Heat Pump; Gas Chromatography; Chemical Stability

Order nr HPT_330_669

Download