PERFORMANCE MONITORING OF A HIGH-TEMPERATURE AIR-TO-WATER HEAT PUMP WITH INJECTION CYCLE INSTALLED IN A LOW-INSULATED SINGLE-FAMILY HOUSE IN BELGIUM

This paper deals with the performance monitoring and analysis of a capacity controlled high-temperature air-to-water heat pump with injection cycle. The heat pump has been installed in a low-insulated house in Belgium in March 2010 and is used for space heating in combination with panel radiators or for domestic hot water production. Firstly, we present the behavior of the heat pump in space heating mode as well as in domestic hot water production mode. Secondly, the influence of the injection and of the type of heaters on the performance of the heat pump in space heating mode is presented. Finally, the first results for seasonal performance are presented. These results show that the machine has an efficient control: injection starts for outdoor temperature where it is more efficient than the non injection cycle, defrosting periods are short due to the good management of the speed of the compressor and of the fan of the evaporator. This good behavior allows the heat pump to significantly increase the COP values compared to common air-to-water heat pumps.

Download

Publication type Conf Proceedings Paper

Publication date 23 September 2011

Authors E. Dumont, M. Frère

Keywords air-to-water heat pump, injection cycle, high-temperature, monitoring

Order nr HPP-CONF10

Download