RESEARCH ON EXPANDER OF CO2 TRANSCRITICAL WATER-TO-WATER HEAT PUMP
To improve the efficiency of CO2 transcritical heat pump system, the fundamental measure is using expander to replace throttle. In the present paper, the internal expansion phase change mechanism of expander has been carried out and the simulation test of the phase transition in expander and the experimental study of CO2 transcritical water to water heat pump system with expander have been conducted. The results revealed that a more reasonable explanation to CO2 expansion phase transition could be obtained with nonequilibrium thermodynamic fluctuation theory. During the process of rapid decompression, the pressure and temperature of the working medium declined into the concave curve. At the same time, the mixture of CO2 and lubricating oil were boiling tempestuously, which caused the obvious bubble growth process. In addition, after analyzing the experimental data, we found that the system flow rate was increased with the increasing of the rotating speed and the inlet conditions of expander, and so was the change of expander recover work.