DEVELOPMENT OF ENERGY PERFORMANCE COMPARISON METHOD FOR RESIDENTIAL ELECTRIC APPLIANCES – APPLICATION TO AIR CONDITIONERS

An investigation was carried out on a simple and easy measurement laboratory set-up to compare the energy performance of a non-inverter air-conditioner (AC) and that of an inverter one having the same rated capacity of 12000 BTU/hr. Under part load ratios of 45%, 70%, and 95% and outside-inside temperature differences of from 1K to 7K, it was found that the inverter AC can save 9.3% to 26.9% of electricity consumption over the noninverter one. It also showed that the use of inverter AC instead of non-inverter AC is most effective in reducing energy consumption at a part load ratio of 70%. The coefficient of performance (COP) of the inverter AC and non-inverter AC was found in the range of from 3.4 to 6.3 and from 3.0 to 4.9, respectively. This work has shown a potentially suitable use of the developed set-up to demonstrate the energy performance of other modern electrical appliances that would be used in developing countries to reduce energy consumption and CO2 emissions.

Download

Publication type Conf Proceedings Paper

Publication date 23 September 2011

Authors H. L. Pham, V. D. Nguyen, N. A. Lai, N. A. Nguyen, S. Tokura, S. Nakamura

Keywords Air Conditioner (AC), inverter, comparison, coefficient of performance (COP), energy saving

Order nr HPP-CONF10

Download