EFFICIENCY OF HEAT PUMP SYSTEMS UNDER REAL OPERATING CONDITIONS

Under the direction of the Fraunhofer ISE, two large field tests of newly installed heat pumps have been investigated during last three years. Nearly 200 of air-water, brinewater and water-water heat pump systems were examined under real operating conditions in single and multi-family dwellings. Values of volume flows, temperatures, heat quantity and electricity consumption were collected and sent daily to the Fraunhofer ISE headquarter where they underwent an automatic plausibility check. The results show that the ground source heat pumps are especially promising when it comes to reaching high efficiencies under real conditions. However, there is still a need for optimization in the integration of the unit in the supply system for the house and for the control strategies of the heat pump. Thus, a poorly integrated heat source or an incorrectly designed heat sink can significantly worsen the SPF of the heat pump.

Download

Publication type Conf Proceedings Paper

Publication date 23 September 2011

Authors M. Miara, C. Russ, D. Günther, T. Kramer, H. M. Henning

Keywords heat pumps, monitoring, efficiency, seasonal performance factor, SPF