CAPACITY CONTROL AND OPTIMISED OPERATION OF DOMESTIC HEAT PUMP HEATING SYSTEMS

The efficiency of ground-source heat pump heating systems can be increased considerably by using variable-speed compressors and pumps instead of fixed-speed components. For the heat pump systems evaluated in this work the increase in efficiency is in the range of 15 – 27 %, if the efficiency of the variable-speed compressor can be increased to the same level as the single-speed compressor.

Download

Publication type Conf Proceedings Paper

Publication date 22 May 2008

Authors F. Karlsson, P. Fahlén

Keywords heat pumps, variable-speed, intermittent, seasonal performance, efficiency, control, optimization

Order nr HPP-CONF9