HVAC OPTIONS FOR LOW ENERGY RESIDENTIAL BUILDINGS

Data now available from prototype low energy residences confirm that peak heating and cooling loads can be reduced by factors of 3 to 5, using currently available technologies. This work explores the range of candidate HVAC systems capable of dealing with such fundamentally different load profiles as 8°C balance points, spatially non-uniform loads, and non-negligible thermal capacitance. This paper quantifies peak heating and cooling load reductions in a North American climate, investigates the necessity of ductwork, and examines the role of thermal mass effects in low energy residences. Results reveal surprisingly small differences in overall efficiency among well-designed centralized (ducted) and decentralized vapor-compression heat pump systems employing either mechanical or desiccant dehumidification. Centralized systems offer opportunities for integration of domestic hot water heating, and some types of decentralized systems offer the long-term possibility of being integrated into wall panels or other structural elements. Decentralized system options included DX and secondary loops. Since energy efficiencies are comparable, system selection is therefore likely to be driven by such factors as initial costs, complexity and reliability.

Download

Publication type Conf Proceedings Paper

Publication date 22 May 2008

Authors C. Bullard

Keywords heat pumps, integrated energy systems, low energy house.

Order nr HPP-CONF9

Download