PERFORMANCE ANALYSIS AND MODELING OF A STATIC AIR-TO-WATER HEAT PUMP INTEGRATED IN A SINGLE-FAMILY DWELLING

This paper presents the results of the modeling of a static air-to-water heat pump installed in a single-family dwelling in Belgium. We present a model combining the heat pump and the house. Firstly, we develop sub-models for the heat pump itself, for the heating floor and for the thermal behavior of the house. These sub-models have been validated separately. The results of the heat pump model show good agreement with the experimental results. For the model combining the heat pump and the heating floor, the simulation results are as good as those obtained with the heat pump alone, thus validating the heating floor model. The use of the whole system model shows higher discrepancies with experience because the thermal model of the house is a single zone model. However, simulation results over one year give good total values only 4 to 5% lower than experimental ones.

Download

Publication type Conf Proceedings Paper

Publication date 22 May 2008

Authors E. Dumont, M-E. Duprez, R. Lepore, R. Nourricier, V. Feldheim, M. Frère

Keywords air source heat pumps, model, building thermal model

Order nr HPP-CONF9

Download