{"id":908,"date":"2021-07-07T21:41:47","date_gmt":"2021-07-07T21:41:47","guid":{"rendered":"https:\/\/heatpumpingtechnologies.org\/annex62\/?page_id=908"},"modified":"2022-04-07T11:27:59","modified_gmt":"2022-04-07T11:27:59","slug":"solution-1-1","status":"publish","type":"page","link":"https:\/\/heatpumpingtechnologies.org\/project62\/solution-1-1\/","title":{"rendered":"1.1 Centralized Heat Pump System for The Whole Building"},"content":{"rendered":"<div class=\"container container--no-margin\">\n<p class=\"has-black-color has-text-color has-medium-font-size wp-block-paragraph \"><strong>ONE HEAT PUMP FOR ALL<\/strong><\/p>\n<\/div>\n\n<div class=\"container\">\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-9d6595d7 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:33.33%\"><div class=\"container\">\n<figure class=\"wp-block-image size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/heatpumpingtechnologies.org\/content\/uploads\/sites\/75\/2022\/02\/11.png\" alt=\"\" class=\"wp-image-1118\" width=\"226\" height=\"203\" \/><\/figure>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:66.66%\"><div class=\"container\">\n<div class=\"wp-block-image\"><figure class=\"aligncenter size-large\"><img decoding=\"async\" src=\"https:\/\/heatpumpingtechnologies.org\/content\/uploads\/sites\/75\/2022\/02\/11ubersicht-1024x361.png\" alt=\"\" class=\"wp-image-1159\" \/><\/figure><\/div>\n<\/div><\/div>\n<\/div>\n<\/div>\n\n<div class=\"container\">\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-9d6595d7 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-vertically-aligned-top is-layout-flow wp-block-column-is-layout-flow\"><div class=\"container container--no-margin\">\n<h4 class=\"wp-block-heading\"><strong>Main characteristic of the concept<\/strong><\/h4>\n<\/div>\n\n<div class=\"container container--no-margin\">\n<p class=\"wp-block-paragraph \">One central heat pump system for the whole building, both for space heating and DHW.<\/p>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\"><div class=\"container container--no-margin\">\n<h4 class=\"wp-block-heading\"><strong>Heat distribution and temperatures levels<\/strong><\/h4>\n<\/div>\n\n<div class=\"container container--no-margin\">\n<p class=\"wp-block-paragraph \">The heat distribution occurs through the whole building, which increases the heat losses. The heat pump must be able to provide two temperature levels for space heating and DHW or the heat production needs to always meet the high temperature requirements for DHW.<\/p>\n<\/div><\/div>\n<\/div>\n<\/div>\n\n<div class=\"container\">\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-9d6595d7 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\"><div class=\"container container--no-margin\">\n<h4 class=\"wp-block-heading\"><strong>Size of building, number of apartments<\/strong><\/h4>\n<\/div>\n\n<div class=\"container container--no-margin\">\n<p class=\"wp-block-paragraph \">This solution is a typical solution in SFH. It may also be common to apply in smaller MFB with a small number of apartments. In case of large buildings, more than 1 heat pump may be necessary to meet the required heating capacity (cascade solution).<\/p>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\"><div class=\"container container--no-margin\">\n<h4 class=\"wp-block-heading\"><strong>DHW and storage characteristic<\/strong><\/h4>\n<\/div>\n\n<div class=\"container container--no-margin\">\n<p class=\"wp-block-paragraph \">In the central solution for DHW the heat losses account for a significant part of the energy consumption. Storage tanks for DHW are needed.\u00a0 Separate consideration about legionella needed (for example ultra-filtration).<\/p>\n<\/div><\/div>\n<\/div>\n<\/div>\n\n<div class=\"container\">\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-9d6595d7 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\"><div class=\"container container--no-margin\">\n<h4 class=\"wp-block-heading\"><strong>Energy standard, insulation level&nbsp;<\/strong><\/h4>\n<\/div>\n\n<div class=\"container container--no-margin\">\n<p class=\"wp-block-paragraph \">More suitable for buildings with higher energy standards (Most suitable for buildings with higher energy standards (new buildings). This concept may be used also for buildings with an average energy standard. For poor insulated houses it is not excluded but more challenging to implement.\u00a0<\/p>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\"><div class=\"container container--no-margin\">\n<h4 class=\"wp-block-heading\"><strong>Complexity of installation<\/strong><\/h4>\n<\/div>\n\n<div class=\"container container--no-margin\">\n<p class=\"wp-block-paragraph \">In case of retrofitting, the old heating distribution system may be maintained. In some cases, partial or complete exchange of radiators in each apartment may be required. In case of new buildings, long piping through the whole building is necessary.<\/p>\n<\/div><\/div>\n<\/div>\n<\/div>\n\n<div class=\"container\">\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-9d6595d7 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\"><div class=\"container container--no-margin\">\n<h4 class=\"wp-block-heading\"><strong>Heat Sources<\/strong><\/h4>\n<\/div>\n\n<div class=\"container container--no-margin\">\n<p class=\"wp-block-paragraph \">All heat sources possible. For large buildings with high energy demand the heating capacity can be a restricting factor for the outside air as a heat source. When outside air is used as HP-source, the HPs should preferably be installed on the roof. For larger systems, the sound emissions may be a problem for air-source heat pumps.<\/p>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\"><div class=\"container container--no-margin\">\n<h4 class=\"wp-block-heading\"><strong>Specific issues of the concept<\/strong><\/h4>\n<\/div>\n\n<div class=\"container container--no-margin\">\n<p class=\"wp-block-paragraph \">The old heat generator can be replaced (during retrofitting) without changing the distribution system.<\/p>\n<\/div><\/div>\n<\/div>\n<\/div>\n\n<div class=\"container\">\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-9d6595d7 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\"><div class=\"container container--no-margin\">\n<p class=\"has-black-color has-light-green-cyan-background-color has-text-color has-background wp-block-paragraph \" style=\"font-size:18px\"><strong>Positive aspects<\/strong><\/p>\n<\/div>\n\n<div class=\"container container--no-margin\">\n<ul class=\"wp-block-list\"><li>Good for smaller MFB\u2019s<\/li><li>One controller<\/li><li>Existing distribution maintained<\/li><li>Simple replacement of a gas boiler<\/li><\/ul>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\"><div class=\"container container--no-margin\">\n<p class=\"has-black-color has-pale-pink-background-color has-text-color has-background wp-block-paragraph \" style=\"font-size:18px\"><strong>Negative aspects<\/strong><\/p>\n<\/div>\n\n<div class=\"container container--no-margin\">\n<ul class=\"wp-block-list\"><li>High distribution losses<\/li><\/ul>\n<\/div><\/div>\n<\/div>\n<\/div>\n\n<div class=\"container container--no-margin\">\n<div class=\"wp-block-buttons is-layout-flex wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button\"><a class=\"wp-block-button__link has-white-color has-text-color has-background\" href=\"https:\/\/heatpumpingtechnologies.org\/annex62\/case-studies\/hot-ice-weiz\/\" style=\"background-color:#4e81bd\"><strong>See Example<\/strong><\/a><\/div>\n<\/div>\n<\/div>\n\n<div class=\"container container--no-margin\">\n<hr class=\"wp-block-separator is-style-wide\" \/>\n<\/div>\n\n<div class=\"container container--no-margin\">\n<div class=\"wp-block-buttons is-layout-flex wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button\"><a class=\"wp-block-button__link has-white-color has-text-color has-background\" href=\"https:\/\/heatpumpingtechnologies.org\/annex62\/each-solution-description\/\" style=\"background-color:#4e81bd\"><strong>Description Of Each Solution<\/strong><\/a><\/div>\n<\/div>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>ONE HEAT PUMP FOR ALL Main characteristic of the concept One central heat pump system for the whole building, both&#8230;<\/p>\n","protected":false},"author":7,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_acf_changed":false,"_relevanssi_hide_post":"","_relevanssi_hide_content":"","_relevanssi_pin_for_all":"","_relevanssi_pin_keywords":"","_relevanssi_unpin_keywords":"","_relevanssi_related_keywords":"","_relevanssi_related_include_ids":"","_relevanssi_related_exclude_ids":"","_relevanssi_related_no_append":"","_relevanssi_related_not_related":"","_relevanssi_related_posts":"","_relevanssi_noindex_reason":"","footnotes":""},"class_list":["post-908","page","type-page","status-publish","hentry"],"acf":[],"_links":{"self":[{"href":"https:\/\/heatpumpingtechnologies.org\/project62\/wp-json\/wp\/v2\/pages\/908","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/heatpumpingtechnologies.org\/project62\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/heatpumpingtechnologies.org\/project62\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/heatpumpingtechnologies.org\/project62\/wp-json\/wp\/v2\/users\/7"}],"replies":[{"embeddable":true,"href":"https:\/\/heatpumpingtechnologies.org\/project62\/wp-json\/wp\/v2\/comments?post=908"}],"version-history":[{"count":4,"href":"https:\/\/heatpumpingtechnologies.org\/project62\/wp-json\/wp\/v2\/pages\/908\/revisions"}],"predecessor-version":[{"id":1479,"href":"https:\/\/heatpumpingtechnologies.org\/project62\/wp-json\/wp\/v2\/pages\/908\/revisions\/1479"}],"wp:attachment":[{"href":"https:\/\/heatpumpingtechnologies.org\/project62\/wp-json\/wp\/v2\/media?parent=908"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}