{"id":2473,"date":"2024-04-03T12:52:18","date_gmt":"2024-04-03T12:52:18","guid":{"rendered":"https:\/\/heatpumpingtechnologies.org\/annex62\/?page_id=2473"},"modified":"2025-08-21T14:03:32","modified_gmt":"2025-08-21T14:03:32","slug":"5-1-heat-pump-for-individual-room","status":"publish","type":"page","link":"https:\/\/heatpumpingtechnologies.org\/project62\/5-1-heat-pump-for-individual-room\/","title":{"rendered":"Heat Pump for Individual Room"},"content":{"rendered":"\n<div class=\"wp-block-group is-layout-constrained wp-block-group-is-layout-constrained\"><div class=\"container container--no-margin\">\n<p class=\"has-black-color has-text-color has-medium-font-size wp-block-paragraph \"><strong>E1<\/strong> (5.1)<strong>HEAT PUMP FOR INDIVIDUAL ROOM<\/strong><\/p>\n<\/div>\n\n<div class=\"container\">\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-9d6595d7 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:33.33%\"><div class=\"container\">\n<figure class=\"wp-block-image alignleft size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"246\" height=\"246\" src=\"https:\/\/heatpumpingtechnologies.org\/content\/uploads\/sites\/75\/2025\/08\/51-1.png\" alt=\"\" class=\"wp-image-3219\" srcset=\"https:\/\/heatpumpingtechnologies.org\/content\/uploads\/sites\/75\/2025\/08\/51-1.png 246w, https:\/\/heatpumpingtechnologies.org\/content\/uploads\/sites\/75\/2025\/08\/51-1-150x150.png 150w\" sizes=\"auto, (max-width: 246px) 100vw, 246px\" \/><\/figure>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:66.66%\"><div class=\"container\">\n<figure class=\"wp-block-image aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"361\" src=\"https:\/\/heatpumpingtechnologies.org\/content\/uploads\/sites\/75\/2025\/08\/51ubersicht-1024x361-1.png\" alt=\"\" class=\"wp-image-3292\" srcset=\"https:\/\/heatpumpingtechnologies.org\/content\/uploads\/sites\/75\/2025\/08\/51ubersicht-1024x361-1.png 1024w, https:\/\/heatpumpingtechnologies.org\/content\/uploads\/sites\/75\/2025\/08\/51ubersicht-1024x361-1-300x106.png 300w, https:\/\/heatpumpingtechnologies.org\/content\/uploads\/sites\/75\/2025\/08\/51ubersicht-1024x361-1-768x271.png 768w, https:\/\/heatpumpingtechnologies.org\/content\/uploads\/sites\/75\/2025\/08\/51ubersicht-1024x361-1-400x141.png 400w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n<\/div><\/div>\n<\/div>\n<\/div>\n\n<div class=\"container\">\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-9d6595d7 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-vertically-aligned-top is-layout-flow wp-block-column-is-layout-flow\"><div class=\"container container--no-margin\">\n<h4 class=\"wp-block-heading\"><strong>Main characteristic of the concept<\/strong><\/h4>\n<\/div>\n\n<div class=\"container container--no-margin\">\n<p class=\"wp-block-paragraph \">One heat pump for space heating (or cooling) for one room of the apartment.&nbsp;<\/p>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\"><div class=\"container container--no-margin\">\n<h4 class=\"wp-block-heading\"><strong>Heat distribution and temperatures levels<\/strong><\/h4>\n<\/div>\n\n<div class=\"container container--no-margin\">\n<p class=\"wp-block-paragraph \">The heat distribution (heating only) occurs exclusively through air.&nbsp; This also offers the opportunity of providing cooling in summertime. Since it\u2019s a modular and local system, there is no heat distribution throughout the building.<\/p>\n<\/div><\/div>\n<\/div>\n<\/div>\n\n<div class=\"container\">\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-9d6595d7 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\"><div class=\"container container--no-margin\">\n<h4 class=\"wp-block-heading\"><strong>Size of building, number of apartments<\/strong><\/h4>\n<\/div>\n\n<div class=\"container container--no-margin\">\n<p class=\"wp-block-paragraph \">Very flexible solution for covering heating (and possible cooling) needs.&nbsp; Rather not applicable in large buildings. Strong architectural limitation in existing buildings. For new buildings possible integration in the building fa\u00e7ade.<\/p>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\"><div class=\"container container--no-margin\">\n<h4 class=\"wp-block-heading\"><strong>DHW and storage characteristic<\/strong><\/h4>\n<\/div>\n\n<div class=\"container container--no-margin\">\n<p class=\"wp-block-paragraph \">Separate system is required for DHW.<\/p>\n<\/div><\/div>\n<\/div>\n<\/div>\n\n<div class=\"container\">\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-9d6595d7 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\"><div class=\"container container--no-margin\">\n<h4 class=\"wp-block-heading\"><strong>Energy standard, insulation level&nbsp;<\/strong><\/h4>\n<\/div>\n\n<div class=\"container container--no-margin\">\n<p class=\"wp-block-paragraph \">This concept can be used for space heating in buildings with a high or intermediate energy standards. The heating capacity is limited due to the use of relatively small heat pumps units.&nbsp;<\/p>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\"><div class=\"container container--no-margin\">\n<h4 class=\"wp-block-heading\"><strong>Complexity of installation<\/strong><\/h4>\n<\/div>\n\n<div class=\"container container--no-margin\">\n<p class=\"wp-block-paragraph \">The complexity of installation is very low for each unit. Usually, no need for leaving the apartment in case of refurbishment.<\/p>\n<\/div><\/div>\n<\/div>\n<\/div>\n\n<div class=\"container\">\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-9d6595d7 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\"><div class=\"container container--no-margin\">\n<h4 class=\"wp-block-heading\"><strong>Heat Sources<\/strong><\/h4>\n<\/div>\n\n<div class=\"container container--no-margin\">\n<p class=\"wp-block-paragraph \">This system uses outside air as a source and will preferably be operated with air as the transfer medium for space heating.<\/p>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\"><div class=\"container container--no-margin\">\n<h4 class=\"wp-block-heading\"><strong>Specific issues of the concept<\/strong><\/h4>\n<\/div>\n\n<div class=\"container container--no-margin\">\n<p class=\"wp-block-paragraph \">Heating only. Need for other solution for DHW. Heat distribution occurs exclusively through air. May be noisy.<\/p>\n<\/div><\/div>\n<\/div>\n<\/div>\n\n<div class=\"container\">\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-9d6595d7 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\"><div class=\"container container--no-margin\">\n<p class=\"has-black-color has-light-green-cyan-background-color has-text-color has-background wp-block-paragraph \" style=\"font-size:18px\"><strong>Positive aspects<\/strong><\/p>\n<\/div>\n\n<div class=\"container container--no-margin\">\n<ul class=\"wp-block-list\">\n<li>Flexible solution for smaller MFB\u2019s, especially in case of individual ownership<\/li>\n\n\n\n<li>No distribution losses<\/li>\n<\/ul>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\"><div class=\"container container--no-margin\">\n<p class=\"has-black-color has-pale-pink-background-color has-text-color has-background wp-block-paragraph \" style=\"font-size:18px\"><strong>Negative aspects<\/strong><\/p>\n<\/div>\n\n<div class=\"container container--no-margin\">\n<ul class=\"wp-block-list\">\n<li>Decentral noise of outside-air units<\/li>\n\n\n\n<li>Additional solution for DHW needed<\/li>\n<\/ul>\n<\/div><\/div>\n<\/div>\n<\/div>\n\n<div class=\"container container--no-margin\">\n<div class=\"wp-block-buttons is-layout-flex wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button\"><a class=\"wp-block-button__link has-white-color has-text-color has-background wp-element-button\" style=\"background-color:#4e81bd\"><strong>See Example<\/strong><\/a><\/div>\n<\/div>\n<\/div>\n\n<div class=\"container container--no-margin\">\n<hr class=\"wp-block-separator has-css-opacity is-style-wide\"\/>\n<\/div>\n\n<div class=\"container container--no-margin\">\n<div class=\"wp-block-buttons is-layout-flex wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button\"><a class=\"wp-block-button__link has-white-color has-text-color has-background wp-element-button\" href=\"https:\/\/heatpumpingtechnologies.org\/annex62\/description-of-each-solution\/\" style=\"background-color:#4e81bd\"><strong>Description of Each Solution<\/strong><\/a><\/div>\n<\/div>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-group is-layout-constrained wp-block-group-is-layout-constrained\">\n<div style=\"height:61px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n<div class=\"container container--no-margin\">\n<h2 class=\"wp-block-heading\">Do you have a comment\/suggested change to the description? <\/h2>\n<\/div>\n\n\t<div id=\"respond\" class=\"comment-respond wp-block-post-comments-form\">\n\t\t<h3 id=\"reply-title\" class=\"comment-reply-title\">Leave a Reply<\/h3><p class=\"must-log-in\">You must be <a href=\"https:\/\/heatpumpingtechnologies.org\/project62\/wp-login.php?redirect_to=%2Fproject62%2F5-1-heat-pump-for-individual-room%2F\">logged in<\/a> to post a comment.<\/p>\t<\/div><!-- #respond -->\n\t<\/div>\n","protected":false},"excerpt":{"rendered":"<p>E1 (5.1)HEAT PUMP FOR INDIVIDUAL ROOM Main characteristic of the concept One heat pump for space heating (or cooling) for&#8230;<\/p>\n","protected":false},"author":41,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"open","ping_status":"closed","template":"","meta":{"_acf_changed":false,"_relevanssi_hide_post":"","_relevanssi_hide_content":"","_relevanssi_pin_for_all":"","_relevanssi_pin_keywords":"","_relevanssi_unpin_keywords":"","_relevanssi_related_keywords":"","_relevanssi_related_include_ids":"","_relevanssi_related_exclude_ids":"","_relevanssi_related_no_append":"","_relevanssi_related_not_related":"","_relevanssi_related_posts":"3042,2368,1606,1529,1972,1547","_relevanssi_noindex_reason":"","footnotes":""},"class_list":["post-2473","page","type-page","status-publish","hentry"],"acf":[],"_links":{"self":[{"href":"https:\/\/heatpumpingtechnologies.org\/project62\/wp-json\/wp\/v2\/pages\/2473","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/heatpumpingtechnologies.org\/project62\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/heatpumpingtechnologies.org\/project62\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/heatpumpingtechnologies.org\/project62\/wp-json\/wp\/v2\/users\/41"}],"replies":[{"embeddable":true,"href":"https:\/\/heatpumpingtechnologies.org\/project62\/wp-json\/wp\/v2\/comments?post=2473"}],"version-history":[{"count":4,"href":"https:\/\/heatpumpingtechnologies.org\/project62\/wp-json\/wp\/v2\/pages\/2473\/revisions"}],"predecessor-version":[{"id":3293,"href":"https:\/\/heatpumpingtechnologies.org\/project62\/wp-json\/wp\/v2\/pages\/2473\/revisions\/3293"}],"wp:attachment":[{"href":"https:\/\/heatpumpingtechnologies.org\/project62\/wp-json\/wp\/v2\/media?parent=2473"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}