{"id":2457,"date":"2024-04-03T12:33:29","date_gmt":"2024-04-03T12:33:29","guid":{"rendered":"https:\/\/heatpumpingtechnologies.org\/annex62\/?page_id=2457"},"modified":"2025-08-21T13:54:49","modified_gmt":"2025-08-21T13:54:49","slug":"3-2-heat-pump-for-a-number-of-apartments","status":"publish","type":"page","link":"https:\/\/heatpumpingtechnologies.org\/project62\/3-2-heat-pump-for-a-number-of-apartments\/","title":{"rendered":"Heat Pump for a Number of Apartments"},"content":{"rendered":"\n<div class=\"wp-block-group is-layout-constrained wp-block-group-is-layout-constrained\"><div class=\"container container--no-margin\">\n<p class=\"has-black-color has-text-color has-medium-font-size wp-block-paragraph \"><strong>C2 <\/strong>(3.2)<strong> PARTMENTS GROUPED BY MODE<\/strong><\/p>\n<\/div>\n\n<div class=\"container\">\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-9d6595d7 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:33.33%\"><div class=\"container\">\n<figure class=\"wp-block-image alignleft size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"300\" height=\"298\" src=\"https:\/\/heatpumpingtechnologies.org\/content\/uploads\/sites\/75\/2025\/08\/32-300x298-1.png\" alt=\"\" class=\"wp-image-3282\" srcset=\"https:\/\/heatpumpingtechnologies.org\/content\/uploads\/sites\/75\/2025\/08\/32-300x298-1.png 300w, https:\/\/heatpumpingtechnologies.org\/content\/uploads\/sites\/75\/2025\/08\/32-300x298-1-150x150.png 150w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/figure>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:66.66%\"><div class=\"container\">\n<figure class=\"wp-block-image aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"361\" src=\"https:\/\/heatpumpingtechnologies.org\/content\/uploads\/sites\/75\/2025\/08\/32ubersicht-1024x361-1.png\" alt=\"\" class=\"wp-image-3283\" srcset=\"https:\/\/heatpumpingtechnologies.org\/content\/uploads\/sites\/75\/2025\/08\/32ubersicht-1024x361-1.png 1024w, https:\/\/heatpumpingtechnologies.org\/content\/uploads\/sites\/75\/2025\/08\/32ubersicht-1024x361-1-300x106.png 300w, https:\/\/heatpumpingtechnologies.org\/content\/uploads\/sites\/75\/2025\/08\/32ubersicht-1024x361-1-768x271.png 768w, https:\/\/heatpumpingtechnologies.org\/content\/uploads\/sites\/75\/2025\/08\/32ubersicht-1024x361-1-400x141.png 400w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n<\/div><\/div>\n<\/div>\n<\/div>\n\n<div class=\"container\">\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-9d6595d7 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-vertically-aligned-top is-layout-flow wp-block-column-is-layout-flow\"><div class=\"container container--no-margin\">\n<h4 class=\"wp-block-heading\"><strong>Main characteristic of the concept<\/strong><\/h4>\n<\/div>\n\n<div class=\"container container--no-margin\">\n<p class=\"wp-block-paragraph \">One heat pump system provides one mode (space heating or DHW) for a number of apartments (usually grouped by levels or staircases).<\/p>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\"><div class=\"container container--no-margin\">\n<h4 class=\"wp-block-heading\"><strong>Heat distribution and temperatures levels<\/strong><\/h4>\n<\/div>\n\n<div class=\"container container--no-margin\">\n<p class=\"wp-block-paragraph \">Heat pumps provide heat for only one mode for a section or several sections of the building. The temperature levels provided by the heat pumps are strictly connected to the mode (space heating or DHW). This solution doesn\u2019t provide an integral heat solution for the whole building.&nbsp;&nbsp;<\/p>\n<\/div><\/div>\n<\/div>\n<\/div>\n\n<div class=\"container\">\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-9d6595d7 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\"><div class=\"container container--no-margin\">\n<h4 class=\"wp-block-heading\"><strong>Size of building, number of apartments<\/strong><\/h4>\n<\/div>\n\n<div class=\"container container--no-margin\">\n<p class=\"wp-block-paragraph \">This solution is more suitable for average and especially for large buildings. In smaller buildings there is usually no need for grouping of apartments by mode.&nbsp;<\/p>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\"><div class=\"container container--no-margin\">\n<h4 class=\"wp-block-heading\"><strong>DHW and storage characteristic<\/strong><\/h4>\n<\/div>\n\n<div class=\"container container--no-margin\">\n<p class=\"wp-block-paragraph \">DHW based on heat pump is provided only for a section of the building (group of apartments). Heat pump must meet high temperature requirements of the DHW. Storage tanks for DHW are needed.<\/p>\n<\/div><\/div>\n<\/div>\n<\/div>\n\n<div class=\"container\">\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-9d6595d7 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\"><div class=\"container container--no-margin\">\n<h4 class=\"wp-block-heading\"><strong>Energy standard, insulation level&nbsp;<\/strong><\/h4>\n<\/div>\n\n<div class=\"container container--no-margin\">\n<p class=\"wp-block-paragraph \">This solution is rather suitable in refurbishment cases with lower energy standard. Not practicable for new buildings.<\/p>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\"><div class=\"container container--no-margin\">\n<h4 class=\"wp-block-heading\"><strong>Complexity of installation<\/strong><\/h4>\n<\/div>\n\n<div class=\"container container--no-margin\">\n<p class=\"wp-block-paragraph \">Using heat pumps for one mode only for a group of apartments reduce the complexity of each heat pump installation but increase the complexity of the entire heating and DHW system for the whole the building.<\/p>\n<\/div><\/div>\n<\/div>\n<\/div>\n\n<div class=\"container\">\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-9d6595d7 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\"><div class=\"container container--no-margin\">\n<h4 class=\"wp-block-heading\"><strong>Heat Sources<\/strong><\/h4>\n<\/div>\n\n<div class=\"container container--no-margin\">\n<p class=\"wp-block-paragraph \">All heat sources possible. Depending on the position of heat pumps, some heat sources may be very difficult to implement. For example, it may be difficult to connect ground collectors if the heat pump is not located on the ground floor. In some cases, use of outside air may be difficult due to the sound emissions or heat source capacity. For DHW ventilation exhaust may be used in some cases.<\/p>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\"><div class=\"container container--no-margin\">\n<h4 class=\"wp-block-heading\"><strong>Specific issues of the concept<\/strong><\/h4>\n<\/div>\n\n<div class=\"container container--no-margin\">\n<p class=\"wp-block-paragraph \">This solution allows partly retrofitting of the building. Need of additional heat generators (besides of heat pumps) to cover overall heat needs of the building.<\/p>\n<\/div><\/div>\n<\/div>\n<\/div>\n\n<div class=\"container\">\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-9d6595d7 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\"><div class=\"container container--no-margin\">\n<p class=\"has-black-color has-light-green-cyan-background-color has-text-color has-background wp-block-paragraph \" style=\"font-size:18px\"><strong>Positive aspects<\/strong><\/p>\n<\/div>\n\n<div class=\"container container--no-margin\">\n<ul class=\"wp-block-list\">\n<li>Allows partial retrofitting<\/li>\n\n\n\n<li>Splitting of functions results in optimised efficiencies<\/li>\n<\/ul>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\"><div class=\"container container--no-margin\">\n<p class=\"has-black-color has-pale-pink-background-color has-text-color has-background wp-block-paragraph \" style=\"font-size:18px\"><strong>Negative aspects<\/strong><\/p>\n<\/div>\n\n<div class=\"container container--no-margin\">\n<ul class=\"wp-block-list\">\n<li>Existing systems remain for other apartments<\/li>\n<\/ul>\n<\/div>\n\n<div class=\"container container--no-margin\">\n<p class=\"wp-block-paragraph \"><\/p>\n<\/div><\/div>\n<\/div>\n<\/div>\n\n<div class=\"container container--no-margin\">\n<div class=\"wp-block-buttons is-layout-flex wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button\"><a class=\"wp-block-button__link has-white-color has-text-color has-background wp-element-button\" style=\"background-color:#4e81bd\"><strong>See Example<\/strong><\/a><\/div>\n<\/div>\n<\/div>\n\n<div class=\"container container--no-margin\">\n<hr class=\"wp-block-separator has-css-opacity is-style-wide\"\/>\n<\/div>\n\n<div class=\"container container--no-margin\">\n<div class=\"wp-block-buttons is-layout-flex wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button\"><a class=\"wp-block-button__link has-white-color has-text-color has-background wp-element-button\" href=\"https:\/\/heatpumpingtechnologies.org\/annex62\/description-of-each-solution\/\" style=\"background-color:#4e81bd\"><strong>Description of Each Solution<\/strong><\/a><\/div>\n<\/div>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-group is-layout-constrained wp-block-group-is-layout-constrained\">\n<div style=\"height:61px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n<div class=\"container container--no-margin\">\n<h2 class=\"wp-block-heading\">Do you have a comment\/suggested change to the description? <\/h2>\n<\/div>\n\n\t<div id=\"respond\" class=\"comment-respond wp-block-post-comments-form\">\n\t\t<h3 id=\"reply-title\" class=\"comment-reply-title\">Leave a Reply<\/h3><p class=\"must-log-in\">You must be <a href=\"https:\/\/heatpumpingtechnologies.org\/project62\/wp-login.php?redirect_to=%2Fproject62%2F3-2-heat-pump-for-a-number-of-apartments%2F\">logged in<\/a> to post a comment.<\/p>\t<\/div><!-- #respond -->\n\t<\/div>\n","protected":false},"excerpt":{"rendered":"<p>C2 (3.2) PARTMENTS GROUPED BY MODE Main characteristic of the concept One heat pump system provides one mode (space heating&#8230;<\/p>\n","protected":false},"author":41,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"open","ping_status":"closed","template":"","meta":{"_acf_changed":false,"_relevanssi_hide_post":"","_relevanssi_hide_content":"","_relevanssi_pin_for_all":"","_relevanssi_pin_keywords":"","_relevanssi_unpin_keywords":"","_relevanssi_related_keywords":"","_relevanssi_related_include_ids":"","_relevanssi_related_exclude_ids":"","_relevanssi_related_no_append":"","_relevanssi_related_not_related":"","_relevanssi_related_posts":"2640,2733,1972,3042,3080,2579","_relevanssi_noindex_reason":"","footnotes":""},"class_list":["post-2457","page","type-page","status-publish","hentry"],"acf":[],"_links":{"self":[{"href":"https:\/\/heatpumpingtechnologies.org\/project62\/wp-json\/wp\/v2\/pages\/2457","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/heatpumpingtechnologies.org\/project62\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/heatpumpingtechnologies.org\/project62\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/heatpumpingtechnologies.org\/project62\/wp-json\/wp\/v2\/users\/41"}],"replies":[{"embeddable":true,"href":"https:\/\/heatpumpingtechnologies.org\/project62\/wp-json\/wp\/v2\/comments?post=2457"}],"version-history":[{"count":5,"href":"https:\/\/heatpumpingtechnologies.org\/project62\/wp-json\/wp\/v2\/pages\/2457\/revisions"}],"predecessor-version":[{"id":3284,"href":"https:\/\/heatpumpingtechnologies.org\/project62\/wp-json\/wp\/v2\/pages\/2457\/revisions\/3284"}],"wp:attachment":[{"href":"https:\/\/heatpumpingtechnologies.org\/project62\/wp-json\/wp\/v2\/media?parent=2457"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}