{"id":1122,"date":"2022-02-17T15:04:26","date_gmt":"2022-02-17T15:04:26","guid":{"rendered":"https:\/\/heatpumpingtechnologies.org\/annex62\/?page_id=1122"},"modified":"2025-08-21T13:31:29","modified_gmt":"2025-08-21T13:31:29","slug":"solution-1-2","status":"publish","type":"page","link":"https:\/\/heatpumpingtechnologies.org\/project62\/solution-1-2\/","title":{"rendered":"Centralized Heat Pump System for The Whole Building"},"content":{"rendered":"\n<div class=\"wp-block-group is-layout-constrained wp-block-group-is-layout-constrained\"><div class=\"container container--no-margin\">\n<p class=\"has-black-color has-text-color has-medium-font-size wp-block-paragraph \"><strong>A2<\/strong> (1.2) <strong style=\"font-weight: bold;\">ONE FOR HEATING, ONE FOR DHW<\/strong><\/p>\n<\/div>\n\n<div class=\"container\">\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-9d6595d7 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:33.33%\"><div class=\"container\">\n<figure class=\"wp-block-image alignleft size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"1578\" height=\"1573\" src=\"https:\/\/heatpumpingtechnologies.org\/content\/uploads\/sites\/75\/2024\/06\/a2.png\" alt=\"\" class=\"wp-image-2649\" srcset=\"https:\/\/heatpumpingtechnologies.org\/content\/uploads\/sites\/75\/2024\/06\/a2.png 1578w, https:\/\/heatpumpingtechnologies.org\/content\/uploads\/sites\/75\/2024\/06\/a2-300x300.png 300w, https:\/\/heatpumpingtechnologies.org\/content\/uploads\/sites\/75\/2024\/06\/a2-1024x1021.png 1024w, https:\/\/heatpumpingtechnologies.org\/content\/uploads\/sites\/75\/2024\/06\/a2-150x150.png 150w, https:\/\/heatpumpingtechnologies.org\/content\/uploads\/sites\/75\/2024\/06\/a2-768x766.png 768w, https:\/\/heatpumpingtechnologies.org\/content\/uploads\/sites\/75\/2024\/06\/a2-1536x1531.png 1536w, https:\/\/heatpumpingtechnologies.org\/content\/uploads\/sites\/75\/2024\/06\/a2-400x400.png 400w\" sizes=\"auto, (max-width: 1578px) 100vw, 1578px\" \/><\/figure>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:66.66%\"><div class=\"container\">\n<figure class=\"wp-block-image aligncenter size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"444\" src=\"https:\/\/heatpumpingtechnologies.org\/content\/uploads\/sites\/75\/2024\/06\/a2-family-1024x444.png\" alt=\"\" class=\"wp-image-2651\" srcset=\"https:\/\/heatpumpingtechnologies.org\/content\/uploads\/sites\/75\/2024\/06\/a2-family-1024x444.png 1024w, https:\/\/heatpumpingtechnologies.org\/content\/uploads\/sites\/75\/2024\/06\/a2-family-300x130.png 300w, https:\/\/heatpumpingtechnologies.org\/content\/uploads\/sites\/75\/2024\/06\/a2-family-768x333.png 768w, https:\/\/heatpumpingtechnologies.org\/content\/uploads\/sites\/75\/2024\/06\/a2-family-1536x667.png 1536w, https:\/\/heatpumpingtechnologies.org\/content\/uploads\/sites\/75\/2024\/06\/a2-family-2048x889.png 2048w, https:\/\/heatpumpingtechnologies.org\/content\/uploads\/sites\/75\/2024\/06\/a2-family-400x174.png 400w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n<\/div><\/div>\n<\/div>\n<\/div>\n\n<div class=\"container\">\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-9d6595d7 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-vertically-aligned-top is-layout-flow wp-block-column-is-layout-flow\"><div class=\"container container--no-margin\">\n<h4 class=\"wp-block-heading\"><strong>Main characteristic of the concept<\/strong><\/h4>\n<\/div>\n\n<div class=\"container container--no-margin\">\n<p class=\"wp-block-paragraph \">One heat pump system for each mode. One for space heating, separate one for DHW.<\/p>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\"><div class=\"container container--no-margin\">\n<h4 class=\"wp-block-heading\"><strong>Heat distribution and temperatures levels<\/strong><\/h4>\n<\/div>\n\n<div class=\"container container--no-margin\">\n<p class=\"wp-block-paragraph \">Because of the separate production of space heating and DHW and, consequently, different supply temperature levels, each heat pump may be optimized for own purpose. It includes, for example, the capacity of the heat pump and the refrigerant.<\/p>\n<\/div><\/div>\n<\/div>\n<\/div>\n\n<div class=\"container\">\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-9d6595d7 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\"><div class=\"container container--no-margin\">\n<h4 class=\"wp-block-heading\"><strong>Size of building, number of apartments<\/strong><\/h4>\n<\/div>\n\n<div class=\"container container--no-margin\">\n<p class=\"wp-block-paragraph \">This solution is suitable for all sizes of buildings, but often used for larger buildings.<\/p>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\"><div class=\"container container--no-margin\">\n<h4 class=\"wp-block-heading\"><strong>DHW and storage characteristic<\/strong><\/h4>\n<\/div>\n\n<div class=\"container container--no-margin\">\n<p class=\"wp-block-paragraph \">Storage tanks for DHW are needed. Heat pump must meet high temperature requirements of the DHW. Central distribution of DHW results in high distribution energy losses.&nbsp;Separate consideration about legionella needed (for example ultra-filtration).<\/p>\n<\/div><\/div>\n<\/div>\n<\/div>\n\n<div class=\"container\">\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-9d6595d7 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\"><div class=\"container container--no-margin\">\n<h4 class=\"wp-block-heading\"><strong>Energy standard, insulation level&nbsp;<\/strong><\/h4>\n<\/div>\n\n<div class=\"container container--no-margin\">\n<p class=\"wp-block-paragraph \">This concept can be used for buildings with a high, as well as a low level of insulation. In new buildings two temperature levels are possible, which allows to optimise each heat pump for certain temperature level. Using two different heat pumps allows implementation of different refrigerants.<\/p>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\"><div class=\"container container--no-margin\">\n<h4 class=\"wp-block-heading\"><strong>Complexity of installation<\/strong><\/h4>\n<\/div>\n\n<div class=\"container container--no-margin\">\n<p class=\"wp-block-paragraph \">In case of retrofitting, the old heating distribution system can be maintained. In some cases, partial or complete exchange of radiators in each apartment may be required. In case of new buildings, long piping through the whole building is necessary.<\/p>\n<\/div><\/div>\n<\/div>\n<\/div>\n\n<div class=\"container\">\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-9d6595d7 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\"><div class=\"container container--no-margin\">\n<h4 class=\"wp-block-heading\"><strong>Heat Sources<\/strong><\/h4>\n<\/div>\n\n<div class=\"container container--no-margin\">\n<p class=\"wp-block-paragraph \">All heat sources possible. Using two different heat pumps allows also for using two different heat sources. For large buildings with high energy demand the heating capacity may be a limitation factor for outside air as a heat source. When outside air is used as HP-source, the HPs preferably should be installed on the roof. For larger systems the sound emissions may be a problem for air source heat pumps.<\/p>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\"><div class=\"container container--no-margin\">\n<h4 class=\"wp-block-heading\"><strong>Specific issues of the concept<\/strong><\/h4>\n<\/div>\n\n<div class=\"container container--no-margin\">\n<p class=\"wp-block-paragraph \">The old heat generators may be replaced (during retrofitting) without changing the distribution system. Specific heat pumps for each mode may be beneficial in terms of lower capacity needed, used refrigerants, chosen heat sources, etc.).<\/p>\n<\/div><\/div>\n<\/div>\n<\/div>\n\n<div class=\"container\">\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-9d6595d7 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\"><div class=\"container container--no-margin\">\n<p class=\"has-black-color has-light-green-cyan-background-color has-text-color has-background wp-block-paragraph \" style=\"font-size:18px\"><strong>Positive aspects<\/strong><\/p>\n<\/div>\n\n<div class=\"container container--no-margin\">\n<ul class=\"wp-block-list\">\n<li>Good for larger MFB\u2019s<\/li>\n\n\n\n<li>Splitting functions may lead to higher efficiencies<\/li>\n<\/ul>\n<\/div>\n\n<div class=\"container container--no-margin\">\n<p class=\"wp-block-paragraph \"><\/p>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\"><div class=\"container container--no-margin\">\n<p class=\"has-black-color has-pale-pink-background-color has-text-color has-background wp-block-paragraph \" style=\"font-size:18px\"><strong>Negative aspects<\/strong><\/p>\n<\/div>\n\n<div class=\"container container--no-margin\">\n<ul class=\"wp-block-list\">\n<li>High distribution losses <\/li>\n<\/ul>\n<\/div>\n\n<div class=\"container container--no-margin\">\n<p class=\"wp-block-paragraph \"><\/p>\n<\/div><\/div>\n<\/div>\n<\/div>\n\n<div class=\"container container--no-margin\">\n<div class=\"wp-block-buttons is-layout-flex wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button\"><a class=\"wp-block-button__link has-white-color has-text-color has-background wp-element-button\" href=\"https:\/\/heatpumpingtechnologies.org\/annex62\/case-studies\/nice\/\" style=\"background-color:#4e81bd\"><strong>See Example<\/strong><\/a><\/div>\n<\/div>\n<\/div>\n\n<div class=\"container container--no-margin\">\n<hr class=\"wp-block-separator has-css-opacity is-style-wide\"\/>\n<\/div>\n\n<div class=\"container container--no-margin\">\n<div class=\"wp-block-buttons is-layout-flex wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button\"><a class=\"wp-block-button__link has-white-color has-text-color has-background wp-element-button\" href=\"https:\/\/heatpumpingtechnologies.org\/annex62\/each-solution-description\/\" style=\"background-color:#4e81bd\"><strong>Description of Each Solution<\/strong><\/a><\/div>\n<\/div>\n<\/div>\n\n<div class=\"container container--no-margin\">\n<p class=\"wp-block-paragraph \"><\/p>\n<\/div><\/div>\n","protected":false},"excerpt":{"rendered":"<p>A2 (1.2) ONE FOR HEATING, ONE FOR DHW Main characteristic of the concept One heat pump system for each mode&#8230;.<\/p>\n","protected":false},"author":7,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_acf_changed":false,"_relevanssi_hide_post":"","_relevanssi_hide_content":"","_relevanssi_pin_for_all":"","_relevanssi_pin_keywords":"","_relevanssi_unpin_keywords":"","_relevanssi_related_keywords":"","_relevanssi_related_include_ids":"","_relevanssi_related_exclude_ids":"","_relevanssi_related_no_append":"","_relevanssi_related_not_related":"","_relevanssi_related_posts":"2368,2640,1606,3080,2733,2754","_relevanssi_noindex_reason":"","footnotes":""},"class_list":["post-1122","page","type-page","status-publish","hentry"],"acf":[],"_links":{"self":[{"href":"https:\/\/heatpumpingtechnologies.org\/project62\/wp-json\/wp\/v2\/pages\/1122","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/heatpumpingtechnologies.org\/project62\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/heatpumpingtechnologies.org\/project62\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/heatpumpingtechnologies.org\/project62\/wp-json\/wp\/v2\/users\/7"}],"replies":[{"embeddable":true,"href":"https:\/\/heatpumpingtechnologies.org\/project62\/wp-json\/wp\/v2\/comments?post=1122"}],"version-history":[{"count":5,"href":"https:\/\/heatpumpingtechnologies.org\/project62\/wp-json\/wp\/v2\/pages\/1122\/revisions"}],"predecessor-version":[{"id":3259,"href":"https:\/\/heatpumpingtechnologies.org\/project62\/wp-json\/wp\/v2\/pages\/1122\/revisions\/3259"}],"wp:attachment":[{"href":"https:\/\/heatpumpingtechnologies.org\/project62\/wp-json\/wp\/v2\/media?parent=1122"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}