{"id":435,"date":"2019-01-28T10:55:39","date_gmt":"2019-01-28T10:55:39","guid":{"rendered":"https:\/\/heatpumpingtechnologies.org\/annex62\/?page_id=435"},"modified":"2025-09-04T11:17:47","modified_gmt":"2025-09-04T11:17:47","slug":"nice","status":"publish","type":"case_studies","link":"https:\/\/heatpumpingtechnologies.org\/project62\/case-studies\/nice\/","title":{"rendered":"Nice"},"content":{"rendered":"<div class=\"container container--no-margin classic-editor\"><p>This first part of ecodistrict gathers 7 buildings of dwellings, offices, a nursery; representing almost 20000 m2.<br \/>The district heating system, specific to this ecodistrict is quite innovative. It is based on the treated water rejected by a water treatment plant located 500 m far from the ecodistrict.<br \/>This water is used as the cold source of 8 heat pumps for domestic hot water production and 5 heat pumps for heating and cooling.<\/p>\n<table style=\"height: 181px;\" width=\"654\">\n<tbody>\n<tr>\n<td width=\"140\"><a href=\"https:\/\/heatpumpingtechnologies.org\/content\/uploads\/sites\/75\/2019\/01\/nice-1-1.png\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-medium wp-image-437\" src=\"\/\/staging.heatpumpingtechnologies.hemsida.eu\/content\/uploads\/sites\/75\/2019\/01\/nice-1-1-300x161.png\" alt=\"\" width=\"300\" height=\"161\" srcset=\"https:\/\/heatpumpingtechnologies.org\/content\/uploads\/sites\/75\/2019\/01\/nice-1-1-300x161.png 300w, https:\/\/heatpumpingtechnologies.org\/content\/uploads\/sites\/75\/2019\/01\/nice-1-1-768x412.png 768w, https:\/\/heatpumpingtechnologies.org\/content\/uploads\/sites\/75\/2019\/01\/nice-1-1-400x215.png 400w, https:\/\/heatpumpingtechnologies.org\/content\/uploads\/sites\/75\/2019\/01\/nice-1-1.png 934w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/a><\/td>\n<td width=\"161\"><a href=\"https:\/\/heatpumpingtechnologies.org\/content\/uploads\/sites\/75\/2019\/01\/nice-2.png\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-medium wp-image-438\" src=\"\/\/staging.heatpumpingtechnologies.hemsida.eu\/content\/uploads\/sites\/75\/2019\/01\/nice-2-300x207.png\" alt=\"\" width=\"300\" height=\"207\" srcset=\"https:\/\/heatpumpingtechnologies.org\/content\/uploads\/sites\/75\/2019\/01\/nice-2-300x207.png 300w, https:\/\/heatpumpingtechnologies.org\/content\/uploads\/sites\/75\/2019\/01\/nice-2-768x531.png 768w, https:\/\/heatpumpingtechnologies.org\/content\/uploads\/sites\/75\/2019\/01\/nice-2-400x277.png 400w, https:\/\/heatpumpingtechnologies.org\/content\/uploads\/sites\/75\/2019\/01\/nice-2.png 801w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/a><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><span style=\"color: #c00000;\"><strong>Key facts<\/strong><\/span><\/p>\n<table>\n<tbody>\n<tr>\n<td colspan=\"2\" width=\"300\" height=\"10\"><strong>Buildings (7) <\/strong><\/td>\n<td width=\"19\">\u00a0<\/td>\n<td colspan=\"2\" width=\"300\" height=\"10\"><strong>Heat pump and source<\/strong><\/td>\n<\/tr>\n<tr>\n<td width=\"140\">Location<\/td>\n<td width=\"161\"><em>Nice, France<br \/><\/em><\/td>\n<td width=\"19\">\u00a0<\/td>\n<td width=\"151\">Number of HP<\/td>\n<td width=\"149\"><em>8 x 12kW HP for DHW &amp; 5x HP for heating \/ cooling<br \/><\/em><\/td>\n<\/tr>\n<tr>\n<td width=\"140\">Construction<\/td>\n<td width=\"161\"><em>2012<\/em><\/td>\n<td width=\"19\">\u00a0<\/td>\n<td width=\"151\">Installed power<\/td>\n<td width=\"149\"><em>unknown<\/em><\/td>\n<\/tr>\n<tr>\n<td width=\"140\">Heat distribution<\/td>\n<td width=\"161\"><em>collective<\/em><\/td>\n<td width=\"19\">\u00a0<\/td>\n<td width=\"151\">Operation mode<\/td>\n<td width=\"149\"><em>unknown<\/em><\/td>\n<\/tr>\n<tr>\n<td width=\"140\">Heated area<\/td>\n<td width=\"161\"><em>280 dwellings<\/em><\/td>\n<td width=\"19\">\u00a0<\/td>\n<td width=\"151\">Heat source<\/td>\n<td width=\"149\"><em>treated water from water treatment plant<br \/><\/em><\/td>\n<\/tr>\n<tr>\n<td width=\"140\">Level of insulation<\/td>\n<td width=\"161\"><em>very good<\/em><\/td>\n<td width=\"19\">\u00a0<\/td>\n<td width=\"151\">\u00a0<\/td>\n<td width=\"149\">\u00a0<\/td>\n<\/tr>\n<tr>\n<td width=\"140\">\u00a0<\/td>\n<td width=\"161\">\u00a0<\/td>\n<td width=\"19\">\u00a0<\/td>\n<td width=\"151\">\u00a0<\/td>\n<td width=\"149\">\u00a0<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"300\"><strong>Heating system<\/strong><\/td>\n<td width=\"19\">\u00a0<\/td>\n<td colspan=\"2\" width=\"300\"><strong>Domestic hot water <\/strong><\/td>\n<\/tr>\n<tr>\n<td width=\"140\">Type of system<\/td>\n<td width=\"161\"><em>central<\/em><\/td>\n<td width=\"19\">\u00a0<\/td>\n<td width=\"151\">Type of system<\/td>\n<td width=\"149\"><em>central<\/em><\/td>\n<\/tr>\n<tr>\n<td width=\"140\">Max. temperature<\/td>\n<td width=\"161\"><em>45 \u00b0C<\/em><\/td>\n<td width=\"19\">\u00a0<\/td>\n<td width=\"151\">Max. temperature<\/td>\n<td width=\"149\"><em>55 \u00b0C<\/em><\/td>\n<\/tr>\n<tr>\n<td width=\"140\">\u00a0<\/td>\n<td width=\"161\">\u00a0<\/td>\n<td width=\"19\">\u00a0<\/td>\n<td width=\"151\">Hot water storage<\/td>\n<td width=\"149\"><em>17.000 l<\/em><\/td>\n<\/tr>\n<tr>\n<td width=\"140\">\u00a0<\/td>\n<td width=\"161\">\u00a0<\/td>\n<td width=\"19\">\u00a0<\/td>\n<td width=\"151\">\u00a0<\/td>\n<td width=\"149\">\u00a0<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"300\"><strong>Other information <\/strong><\/td>\n<td width=\"19\">\u00a0<\/td>\n<td colspan=\"2\" width=\"300\">\u00a0<\/td>\n<\/tr>\n<tr>\n<td width=\"140\">Substations<\/td>\n<td width=\"161\"><em>4<\/em><\/td>\n<td width=\"19\">\u00a0<\/td>\n<td width=\"151\">Investment costs<\/td>\n<td width=\"149\">1 M\u20ac for geothermal installation<\/td>\n<\/tr>\n<tr>\n<td width=\"140\">Consumption for DHW, heating, cooling<\/td>\n<td width=\"161\"><em>40 kWhep\/m\u00b2a<br \/><\/em><\/td>\n<td width=\"19\">\u00a0<\/td>\n<td width=\"151\">Renewables ratio<\/td>\n<td width=\"149\">69%<\/td>\n<\/tr>\n<tr>\n<td width=\"140\">\u00a0<\/td>\n<td width=\"161\">\u00a0<\/td>\n<td width=\"19\">\u00a0<\/td>\n<td width=\"151\">\u00a0<\/td>\n<td width=\"149\">\u00a0<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><span style=\"color: #c00000;\"><strong>Description of the technical concept<\/strong><\/span><\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter\" src=\"https:\/\/heatpumpingtechnologies.org\/content\/uploads\/sites\/56\/2020\/12\/nicesystem.png\" width=\"449\" height=\"582\" \/><\/p>\n<p>The system consists of:<\/p>\n<ul>\n<li>Boreholes to collect the treated water (the water is collected at a temperature ranging from 12\u00b0C to 25\u00b0C and rejected at a temperature between 7\u00b0C and 30\u00b0C)<\/li>\n<li>5 medium temperature (45\/40\u00b0C) heat pumps (CIAT Dynaciat\u00ae) for heating and cooling (distribution is ensured by fan heaters)<\/li>\n<li>8 high temperature (65\/60\u00b0C) heat pumps (Heliopac Solerpac\u00ae) for domestic hot water production.<\/li>\n<li>Water tanks for domestic hot water storage (17000 liters)<\/li>\n<\/ul>\n<p style=\"text-align: center;\"><a href=\"https:\/\/heatpumpingtechnologies.org\/content\/uploads\/sites\/75\/2023\/11\/fact-sheet-eco-district.pdf\" target=\"_blank\" rel=\"noopener\"><img loading=\"lazy\" decoding=\"async\" class=\"wp-image-342 alignnone aligncenter\" src=\"https:\/\/heatpumpingtechnologies.org\/content\/uploads\/sites\/75\/2018\/02\/unnamed.png\" alt=\"\" width=\"41\" height=\"41\" srcset=\"https:\/\/heatpumpingtechnologies.org\/content\/uploads\/sites\/75\/2018\/02\/unnamed.png 170w, https:\/\/heatpumpingtechnologies.org\/content\/uploads\/sites\/75\/2018\/02\/unnamed-150x150.png 150w\" sizes=\"auto, (max-width: 41px) 100vw, 41px\" \/><\/a><a href=\"https:\/\/heatpumpingtechnologies.org\/content\/uploads\/sites\/75\/2024\/01\/fact-sheet-eco-districtn.pdf\" target=\"_blank\" rel=\"noopener\" data-wplink-edit=\"true\">Case Study Sheet FR Nice<\/a><\/p>\n\n<\/div><div class=\"container container--no-margin\">\n<p class=\"wp-block-paragraph \"><\/p>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>This first part of ecodistrict gathers 7 buildings of dwellings, offices, a nursery; representing almost 20000 m2.The district heating system,&#8230;<\/p>\n","protected":false},"author":7,"featured_media":0,"menu_order":0,"template":"","filters":[],"markets":[23],"applications":[],"class_list":["post-435","case_studies","type-case_studies","status-publish","hentry","markets-france"],"acf":[],"_links":{"self":[{"href":"https:\/\/heatpumpingtechnologies.org\/project62\/wp-json\/wp\/v2\/case_studies\/435","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/heatpumpingtechnologies.org\/project62\/wp-json\/wp\/v2\/case_studies"}],"about":[{"href":"https:\/\/heatpumpingtechnologies.org\/project62\/wp-json\/wp\/v2\/types\/case_studies"}],"author":[{"embeddable":true,"href":"https:\/\/heatpumpingtechnologies.org\/project62\/wp-json\/wp\/v2\/users\/7"}],"version-history":[{"count":4,"href":"https:\/\/heatpumpingtechnologies.org\/project62\/wp-json\/wp\/v2\/case_studies\/435\/revisions"}],"predecessor-version":[{"id":3319,"href":"https:\/\/heatpumpingtechnologies.org\/project62\/wp-json\/wp\/v2\/case_studies\/435\/revisions\/3319"}],"wp:attachment":[{"href":"https:\/\/heatpumpingtechnologies.org\/project62\/wp-json\/wp\/v2\/media?parent=435"}],"wp:term":[{"taxonomy":"filters","embeddable":true,"href":"https:\/\/heatpumpingtechnologies.org\/project62\/wp-json\/wp\/v2\/filters?post=435"},{"taxonomy":"markets","embeddable":true,"href":"https:\/\/heatpumpingtechnologies.org\/project62\/wp-json\/wp\/v2\/markets?post=435"},{"taxonomy":"applications","embeddable":true,"href":"https:\/\/heatpumpingtechnologies.org\/project62\/wp-json\/wp\/v2\/applications?post=435"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}