{"id":3365,"date":"2025-09-15T12:09:41","date_gmt":"2025-09-15T12:09:41","guid":{"rendered":"https:\/\/heatpumpingtechnologies.org\/project62\/?post_type=case_studies&#038;p=3365"},"modified":"2026-03-18T11:13:27","modified_gmt":"2026-03-18T11:13:27","slug":"heat-pump-cascade-and-cooling-system-in-bremen-germany","status":"publish","type":"case_studies","link":"https:\/\/heatpumpingtechnologies.org\/project62\/case-studies\/heat-pump-cascade-and-cooling-system-in-bremen-germany\/","title":{"rendered":"Heat Pump Cascade and Cooling System in Bremen, Germany"},"content":{"rendered":"<div class=\"container\">\n<figure class=\"wp-block-image is-resized\"><img decoding=\"async\" src=\"https:\/\/heatpumpingtechnologies.org\/annex62\/wp-content\/uploads\/sites\/75\/2025\/08\/bildschirmfoto18-8-202594650wwwwaermepumpede.jpeg\" alt=\"\" class=\"wp-image-3132\" style=\"width:539px;height:auto\" \/><\/figure>\n<\/div>\n\n<div class=\"container container--no-margin\">\n<p class=\"wp-block-paragraph \">Heat Pump Cascade and Cooling System in Bremen, Germany<\/p>\n<\/div>\n\n<div class=\"container container--no-margin\">\n<p class=\"wp-block-paragraph \">Located in Bremen, Germany, this modern multi-family residential building was constructed in 2017 with a strong focus on energy efficiency and sustainability. The core idea behind the project was to implement an innovative heating and cooling solution that minimizes carbon emissions while ensuring maximum comfort for residents.<br><br>At the heart of the system is a cascade of Mitsubishi Ecodan air-to-water heat pumps, delivering reliable and efficient heating via low-temperature underfloor heating. This monoenergetic system fully replaces fossil fuels, reflecting a commitment to environmentally friendly technology. Some of the project\u2019s unique selling points (USPs) include its centralized heat pump cascade setup that provides both space heating and domestic hot water with a high degree of redundancy and smart control. The building meets the stringent KfW Efficiency House 55 standard, featuring advanced insulation, triple glazing, and mechanical ventilation to complement the heat pump system\u2019s performance.<br><br>This project serves as an example of how modern heat pump technology can be scaled up effectively for multi-family dwellings, balancing energy savings, sustainability, and occupant comfort. J\u00fcrgen Steinbach explains:<\/p>\n<\/div>\n\n<div class=\"container container--no-margin\">\n<p class=\"wp-block-paragraph \"><br><em>\u201cWe also chose heat pump technology to demonstrate that<br>it can be used to heat a building very economically without<br>using fossil fuels. And our tenants find this very attractive.\u201d<\/em><\/p>\n<\/div>\n\n<div class=\"container container--no-margin\">\n<p class=\"wp-block-paragraph \"><strong>Key facts<\/strong><\/p>\n<\/div>\n\n<div class=\"container container--no-margin\">\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td><strong>Building<\/strong><\/td><td><\/td><td><strong>Heat Pump and Source<\/strong><\/td><td><\/td><\/tr><tr><td>Location<\/td><td><em>Bremen, Germany<\/em><\/td><td>Number of HP<\/td><td><em>3<\/em><\/td><\/tr><tr><td>Construction<\/td><td><em>2017<\/em><\/td><td>Operation mode<\/td><td><em>Monoenergetic<\/em><\/td><\/tr><tr><td>Heated area<\/td><td><em>900 m\u00b2<\/em><\/td><td>Heat source<\/td><td><em>Outside air<\/em><\/td><\/tr><tr><td>No. of apartments<\/td><td><em>8<\/em><\/td><td>Type of system<\/td><td><em>Central<\/em><\/td><\/tr><tr><td>Level of insulation<\/td><td><em>Very good<\/em><\/td><td>Model<\/td><td><em>Mitsubishi Ecodan<\/em><\/td><\/tr><tr><td><\/td><td><\/td><td><\/td><td><\/td><\/tr><tr><td><strong>Heating sytem<\/strong><\/td><td><\/td><td><strong>Domestic Hot Water<\/strong><\/td><td><\/td><\/tr><tr><td>Heating temperature<\/td><td><em>30-35<\/em>\u00b0C<\/td><td>Max. temperature<\/td><td><em>50-53<\/em>\u00b0C<\/td><\/tr><tr><td>Installed power<\/td><td><em>3 x 11,2 kW<\/em><\/td><td><\/td><td><\/td><\/tr><tr><td><\/td><td><\/td><td><\/td><td><\/td><\/tr><tr><td><strong>Other information<\/strong><\/td><td><\/td><td><\/td><td><\/td><\/tr><tr><td>Climatic zone<\/td><td><em>Cfb<\/em><\/td><td>Coefficient of<br>Performance<\/td><td><em>3,0<\/em><\/td><\/tr><tr><td>Refrigerant<\/td><td><em>R1234ze<\/em><\/td><td><\/td><td><\/td><\/tr><\/tbody><\/table><\/figure>\n<\/div>\n\n<div class=\"container container--no-margin\">\n<hr class=\"wp-block-separator has-alpha-channel-opacity\" \/>\n<\/div>\n\n<div class=\"container\">\n<figure class=\"wp-block-image is-resized\"><img decoding=\"async\" src=\"https:\/\/heatpumpingtechnologies.org\/annex62\/wp-content\/uploads\/sites\/75\/2025\/08\/bildschirmfoto18-8-20259361wwwwaermepumpede-1.jpeg\" alt=\"\" class=\"wp-image-3128\" style=\"width:653px;height:auto\" \/><\/figure>\n<\/div>\n\n<div class=\"container container--no-margin\">\n<p class=\"wp-block-paragraph \"><strong>Description of the technical concept<\/strong><\/p>\n<\/div>\n\n<div class=\"container container--no-margin\">\n<p class=\"wp-block-paragraph \">The building\u2019s thermal system uses a modular heat pump cascade with Ecodan air-to-water units configured for staged operation. Each unit activates based on load demand, improving part-load efficiency and ensuring redundancy. A hydraulic module manages flow distribution, while an integrated buffer tank stabilizes supply temperatures during peak or variable demand periods.<\/p>\n<\/div>\n\n<div class=\"container container--no-margin\">\n<p class=\"wp-block-paragraph \">Domestic hot water production is decoupled via a stratified storage system, enabling simultaneous DHW and space heating without performance loss. System control is handled by a central logic controller with temperature sensors and weather-compensated algorithms to optimize runtime and reduce cycling. The system is designed for low supply temperatures, enhancing overall COP and reducing auxiliary energy input.<\/p>\n<\/div>\n\n<div class=\"container container--no-margin\">\n<p class=\"wp-block-paragraph \"><\/p>\n<\/div>\n\n<div class=\"container container--no-margin\">\n<p class=\"wp-block-paragraph \">Case study delivered by: Bundesverband W\u00e4rmepumpe (BWP) &amp; Mitsubishi Electric<\/p>\n<\/div>\n\n<div class=\"container container--no-margin\">\n<p class=\"wp-block-paragraph \"><\/p>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>Heat Pump Cascade and Cooling System in Bremen, Germany Located in Bremen, Germany, this modern multi-family residential building was constructed&#8230;<\/p>\n","protected":false},"author":62,"featured_media":0,"menu_order":0,"template":"","filters":[],"markets":[24],"applications":[7,41],"class_list":["post-3365","case_studies","type-case_studies","status-publish","hentry","markets-germany","applications-buildings","applications-multi-family-buildings"],"acf":[],"_links":{"self":[{"href":"https:\/\/heatpumpingtechnologies.org\/project62\/wp-json\/wp\/v2\/case_studies\/3365","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/heatpumpingtechnologies.org\/project62\/wp-json\/wp\/v2\/case_studies"}],"about":[{"href":"https:\/\/heatpumpingtechnologies.org\/project62\/wp-json\/wp\/v2\/types\/case_studies"}],"author":[{"embeddable":true,"href":"https:\/\/heatpumpingtechnologies.org\/project62\/wp-json\/wp\/v2\/users\/62"}],"version-history":[{"count":4,"href":"https:\/\/heatpumpingtechnologies.org\/project62\/wp-json\/wp\/v2\/case_studies\/3365\/revisions"}],"predecessor-version":[{"id":3581,"href":"https:\/\/heatpumpingtechnologies.org\/project62\/wp-json\/wp\/v2\/case_studies\/3365\/revisions\/3581"}],"wp:attachment":[{"href":"https:\/\/heatpumpingtechnologies.org\/project62\/wp-json\/wp\/v2\/media?parent=3365"}],"wp:term":[{"taxonomy":"filters","embeddable":true,"href":"https:\/\/heatpumpingtechnologies.org\/project62\/wp-json\/wp\/v2\/filters?post=3365"},{"taxonomy":"markets","embeddable":true,"href":"https:\/\/heatpumpingtechnologies.org\/project62\/wp-json\/wp\/v2\/markets?post=3365"},{"taxonomy":"applications","embeddable":true,"href":"https:\/\/heatpumpingtechnologies.org\/project62\/wp-json\/wp\/v2\/applications?post=3365"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}