{"id":3005,"date":"2025-03-26T11:23:35","date_gmt":"2025-03-26T11:23:35","guid":{"rendered":"https:\/\/heatpumpingtechnologies.org\/annex62\/?page_id=3005"},"modified":"2025-09-12T14:43:11","modified_gmt":"2025-09-12T14:43:11","slug":"de015-two-different-buildings-two-identical-systems","status":"publish","type":"case_studies","link":"https:\/\/heatpumpingtechnologies.org\/project62\/case-studies\/de015-two-different-buildings-two-identical-systems\/","title":{"rendered":"DE015 Two Different Buildings, Two Identical Systems"},"content":{"rendered":"\n<div class=\"wp-block-group is-layout-constrained wp-block-group-is-layout-constrained\">\n<div class=\"wp-block-group is-layout-constrained wp-block-group-is-layout-constrained\"><div class=\"container container--no-margin\">\n<p class=\"wp-block-paragraph \" style=\"font-size:25px\">Wilsdruff, Germany<\/p>\n<\/div>\n\n\n<div class=\"wp-block-group is-layout-constrained wp-block-group-is-layout-constrained\"><div class=\"container container--no-margin\">\n<p class=\"wp-block-paragraph \">Two multi-family buildings (MFBs) were built in the town of Wilsdruff near the city of Dresden. They have different sizes and were approached architecturally differently but still, both buildings have identical heating concepts.<\/p>\n<\/div>\n\n<div class=\"container container--no-margin\">\n<p class=\"wp-block-paragraph \">Keeping the systems quiet was crucial because the MFBs lie in a neighborhood with especially strict noise control regulations. Thanks to specifically designed fan blades the sound level never goes above 58 dB(A), even when the system is running on full load.<\/p>\n<\/div>\n\n<div class=\"container container--no-margin\">\n<p class=\"wp-block-paragraph \">Even before the German <em>Geb\u00e4udeenergiegesetz GEG <\/em>(Buildings Energy Act) was reformed, the planners decided to go for the hybrid heating concept of heat pumps and gas boilers. The technical and financial advantages were decisive, promising high efficiency and low costs.<\/p>\n<\/div>\n\n<div class=\"container container--no-margin\">\n<p class=\"wp-block-paragraph \">Choosing heat pumps even without regulations in mind proves that this technology already makes sense from a economic and a practical point of view.<\/p>\n<\/div>\n\n<div class=\"container\">\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"2560\" height=\"1707\" src=\"https:\/\/heatpumpingtechnologies.org\/content\/uploads\/sites\/75\/2025\/03\/de015-building-min-scaled.jpg\" alt=\"\" class=\"wp-image-3006\" srcset=\"https:\/\/heatpumpingtechnologies.org\/content\/uploads\/sites\/75\/2025\/03\/de015-building-min-scaled.jpg 2560w, https:\/\/heatpumpingtechnologies.org\/content\/uploads\/sites\/75\/2025\/03\/de015-building-min-300x200.jpg 300w, https:\/\/heatpumpingtechnologies.org\/content\/uploads\/sites\/75\/2025\/03\/de015-building-min-1024x683.jpg 1024w, https:\/\/heatpumpingtechnologies.org\/content\/uploads\/sites\/75\/2025\/03\/de015-building-min-768x512.jpg 768w, https:\/\/heatpumpingtechnologies.org\/content\/uploads\/sites\/75\/2025\/03\/de015-building-min-1536x1024.jpg 1536w, https:\/\/heatpumpingtechnologies.org\/content\/uploads\/sites\/75\/2025\/03\/de015-building-min-2048x1365.jpg 2048w, https:\/\/heatpumpingtechnologies.org\/content\/uploads\/sites\/75\/2025\/03\/de015-building-min-400x267.jpg 400w\" sizes=\"auto, (max-width: 2560px) 100vw, 2560px\" \/><figcaption class=\"wp-element-caption\">Credits: bwp Bundesverband W\u00e4rmepumpe<\/figcaption><\/figure>\n<\/div><\/div>\n\n\n<div class=\"container container--no-margin\">\n<p class=\"wp-block-paragraph \"><strong>Lessons learned<\/strong><\/p>\n<\/div>\n\n<div class=\"container container--no-margin\">\n<ul class=\"wp-block-list\">\n<li>Regulations are not the only driver for installing heat pumps. Economic and practical advantages are plenty.<\/li>\n<\/ul>\n<\/div>\n\n<div class=\"container container--no-margin\">\n<p class=\"wp-block-paragraph \"><strong>Key facts<\/strong><\/p>\n<\/div>\n\n\n<div class=\"wp-block-group is-layout-constrained wp-block-group-is-layout-constrained\"><div class=\"container container--no-margin\">\n<figure class=\"wp-block-table is-style-stripes\"><table><tbody><tr><td><strong>Building<\/strong><\/td><td><\/td><td><strong>Heat Pump and Source<\/strong><\/td><td><\/td><\/tr><tr><td>Location<\/td><td><em>Wilsdruff, Germany<\/em><\/td><td>Number of HP<\/td><td><em>2 (1 for each <\/em><br><em>building)<\/em><\/td><\/tr><tr><td>Construction<\/td><td><em>2022<\/em><\/td><td>Operation mode<\/td><td><em>bivalent<\/em><\/td><\/tr><tr><td>No. of buildings<\/td><td><em>2<\/em><\/td><td>Heat source<\/td><td><em>air<\/em><\/td><\/tr><tr><td>Level of insulation<\/td><td><em>good<\/em><\/td><td>Type of system<\/td><td><em>central<\/em><\/td><\/tr><tr><td>Heated space<\/td><td><em>320 m\u00b2<\/em><br><em>550 m\u00b2<\/em><\/td><td>Model<\/td><td><em>BR\u00d6TJE BLW NEO<\/em><br><em><strong>12 <\/strong>&amp; <strong>18<\/strong><\/em><\/td><\/tr><tr><td><\/td><td><\/td><td>Installed power<\/td><td><em>12 kW<br>16 kW<\/em><\/td><\/tr><tr><td><\/td><td><\/td><td>Heat distribution<\/td><td><em>underfloor<\/em><\/td><\/tr><tr><td><strong>Other information<\/strong><\/td><td><\/td><td><strong>DHW<\/strong><\/td><td><\/td><\/tr><tr><td>Climate Zone<\/td><td><em>Cfb<\/em><\/td><td>Device<\/td><td><em>Central gas con-<br>densing boilers<\/em><\/td><\/tr><tr><td>COP<\/td><td><em>4.02 (12)<\/em><br><em>4.25 (18)<\/em><\/td><td><\/td><td><\/td><\/tr><tr><td>Refrigerant<\/td><td><em>R410A<\/em><\/td><td><\/td><td><\/td><\/tr><tr><td><\/td><td><\/td><td><\/td><td><\/td><\/tr><\/tbody><\/table><\/figure>\n<\/div>\n\n<div class=\"container container--no-margin\">\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n<\/div><\/div>\n\n\n<div class=\"container\">\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"1021\" height=\"756\" src=\"https:\/\/heatpumpingtechnologies.org\/content\/uploads\/sites\/75\/2025\/03\/de015-scheme.png\" alt=\"\" class=\"wp-image-3007\" srcset=\"https:\/\/heatpumpingtechnologies.org\/content\/uploads\/sites\/75\/2025\/03\/de015-scheme.png 1021w, https:\/\/heatpumpingtechnologies.org\/content\/uploads\/sites\/75\/2025\/03\/de015-scheme-300x222.png 300w, https:\/\/heatpumpingtechnologies.org\/content\/uploads\/sites\/75\/2025\/03\/de015-scheme-768x569.png 768w, https:\/\/heatpumpingtechnologies.org\/content\/uploads\/sites\/75\/2025\/03\/de015-scheme-400x296.png 400w\" sizes=\"auto, (max-width: 1021px) 100vw, 1021px\" \/><\/figure>\n<\/div>\n\n<div class=\"container container--no-margin\">\n<p class=\"wp-block-paragraph \"><strong>Description of the technical concept<\/strong><\/p>\n<\/div>\n\n<div class=\"container container--no-margin\">\n<p class=\"wp-block-paragraph \">Space Heating (SH) is provided in each building by a central heat pump. Additionally a gas condensing boiler is equipped in each MFB that serve purely for the production of DHW.<\/p>\n<\/div>\n\n<div class=\"container container--no-margin\">\n<p class=\"wp-block-paragraph \">(Buffer) storages are not included in the flow chart.<\/p>\n<\/div>\n\n\n<div class=\"wp-block-group is-layout-constrained wp-block-group-is-layout-constrained\"><div class=\"container container--no-margin\">\n<div class=\"wp-block-buttons is-horizontal is-content-justification-center is-layout-flex wp-container-core-buttons-is-layout-b989473c wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button has-custom-width wp-block-button__width-50 has-custom-font-size is-style-outline has-medium-font-size is-style-outline--1\" style=\"text-transform:none\"><a class=\"wp-block-button__link has-vivid-cyan-blue-color has-white-background-color has-text-color has-background has-text-align-center wp-element-button\" href=\"https:\/\/heatpumpingtechnologies.org\/content\/uploads\/sites\/75\/2025\/03\/de015fact-sheet-wilsdruff.pdf\" style=\"border-radius:5px\"><img loading=\"lazy\" decoding=\"async\" width=\"300\" height=\"84\" class=\"wp-image-2196\" style=\"width: 300px;\" src=\"https:\/\/heatpumpingtechnologies.org\/content\/uploads\/sites\/75\/2024\/02\/fact-sheet-button-pic.png\" alt=\"\" srcset=\"https:\/\/heatpumpingtechnologies.org\/content\/uploads\/sites\/75\/2024\/02\/fact-sheet-button-pic.png 845w, https:\/\/heatpumpingtechnologies.org\/content\/uploads\/sites\/75\/2024\/02\/fact-sheet-button-pic-300x84.png 300w, https:\/\/heatpumpingtechnologies.org\/content\/uploads\/sites\/75\/2024\/02\/fact-sheet-button-pic-768x215.png 768w, https:\/\/heatpumpingtechnologies.org\/content\/uploads\/sites\/75\/2024\/02\/fact-sheet-button-pic-400x112.png 400w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/a><\/div>\n<\/div>\n<\/div>\n\n<div class=\"container container--no-margin\">\n<p class=\"has-text-align-center wp-block-paragraph \"><strong>DE015 Two Different Buildings, Two Identical Systems<\/strong><\/p>\n<\/div><\/div>\n<\/div>\n\n\n<div class=\"container container--no-margin\">\n<p class=\"wp-block-paragraph \">Case study delivered by: Bundesverband W\u00e4rmepumpe bwp <a href=\"https:\/\/b2electrification.org\/ravens-crossing-how-community-went-all-electric\"><\/a><a href=\"https:\/\/www.waermepumpe.de\/presse\/referenzobjekte\/bwp-datenbank\/vom-fossilen-fernwaermenetz-zur-gruenen-quartiersloesung\/\"><\/a><a href=\"https:\/\/www.waermepumpe.de\/presse\/referenzobjekte\/bwp-datenbank\/hybridloesung-fuer-zwei-hamburger-mehrfamilienhaeuser\/\"><\/a><a href=\"https:\/\/www.waermepumpe.de\/presse\/referenzobjekte\/bwp-datenbank\/mehrfamilienhaus-cuxhaven\/\"><\/a><a href=\"https:\/\/www.waermepumpe.de\/presse\/referenzobjekte\/bwp-datenbank\/waermepumpe-hybridheizung-im-mietwohnungsbau\/\">BWP-Datenbank | Bundesverband W\u00e4rmepumpe (BWP) e.V.<\/a><\/p>\n<\/div><\/div>\n","protected":false},"excerpt":{"rendered":"<p>Wilsdruff, Germany Two multi-family buildings (MFBs) were built in the town of Wilsdruff near the city of Dresden. They have&#8230;<\/p>\n","protected":false},"author":41,"featured_media":0,"menu_order":0,"template":"","filters":[],"markets":[24],"applications":[7,41],"class_list":["post-3005","case_studies","type-case_studies","status-publish","hentry","markets-germany","applications-buildings","applications-multi-family-buildings"],"acf":[],"_links":{"self":[{"href":"https:\/\/heatpumpingtechnologies.org\/project62\/wp-json\/wp\/v2\/case_studies\/3005","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/heatpumpingtechnologies.org\/project62\/wp-json\/wp\/v2\/case_studies"}],"about":[{"href":"https:\/\/heatpumpingtechnologies.org\/project62\/wp-json\/wp\/v2\/types\/case_studies"}],"author":[{"embeddable":true,"href":"https:\/\/heatpumpingtechnologies.org\/project62\/wp-json\/wp\/v2\/users\/41"}],"version-history":[{"count":3,"href":"https:\/\/heatpumpingtechnologies.org\/project62\/wp-json\/wp\/v2\/case_studies\/3005\/revisions"}],"predecessor-version":[{"id":3024,"href":"https:\/\/heatpumpingtechnologies.org\/project62\/wp-json\/wp\/v2\/case_studies\/3005\/revisions\/3024"}],"wp:attachment":[{"href":"https:\/\/heatpumpingtechnologies.org\/project62\/wp-json\/wp\/v2\/media?parent=3005"}],"wp:term":[{"taxonomy":"filters","embeddable":true,"href":"https:\/\/heatpumpingtechnologies.org\/project62\/wp-json\/wp\/v2\/filters?post=3005"},{"taxonomy":"markets","embeddable":true,"href":"https:\/\/heatpumpingtechnologies.org\/project62\/wp-json\/wp\/v2\/markets?post=3005"},{"taxonomy":"applications","embeddable":true,"href":"https:\/\/heatpumpingtechnologies.org\/project62\/wp-json\/wp\/v2\/applications?post=3005"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}