{"id":2822,"date":"2025-03-07T14:51:24","date_gmt":"2025-03-07T14:51:24","guid":{"rendered":"https:\/\/heatpumpingtechnologies.org\/annex62\/?page_id=2822"},"modified":"2025-09-12T14:48:02","modified_gmt":"2025-09-12T14:48:02","slug":"fr006-retrofit-of-112-flats-with-no-outdoor-unit","status":"publish","type":"case_studies","link":"https:\/\/heatpumpingtechnologies.org\/project62\/case-studies\/fr006-retrofit-of-112-flats-with-no-outdoor-unit\/","title":{"rendered":"FR006 Retrofit of 112 flats with no outdoor unit"},"content":{"rendered":"\n<div class=\"wp-block-group is-layout-constrained wp-block-group-is-layout-constrained\">\n<div class=\"wp-block-group is-layout-constrained wp-block-group-is-layout-constrained\">\n<div class=\"wp-block-group is-layout-constrained wp-block-group-is-layout-constrained\"><div class=\"container container--no-margin\">\n<p class=\"wp-block-paragraph \" style=\"font-size:25px\"><strong>Exhaust air Heat pump for SH and DHW<\/strong><\/p>\n<\/div><\/div>\n\n\n<div class=\"container container--no-margin\">\n<p class=\"wp-block-paragraph \">The replacement of a fossil fuel central heating system with individual exhaust air HPs<br>in each flat offered a ready-made compact solution for ventilation, SH and DHW.<\/p>\n<\/div>\n\n<div class=\"container\">\n<figure class=\"wp-block-image aligncenter size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"539\" height=\"428\" src=\"https:\/\/heatpumpingtechnologies.org\/content\/uploads\/sites\/75\/2025\/03\/fr006-house-1.jpg\" alt=\"\" class=\"wp-image-2824\" style=\"aspect-ratio:1.6289592760180995;width:626px;height:auto\" srcset=\"https:\/\/heatpumpingtechnologies.org\/content\/uploads\/sites\/75\/2025\/03\/fr006-house-1.jpg 539w, https:\/\/heatpumpingtechnologies.org\/content\/uploads\/sites\/75\/2025\/03\/fr006-house-1-300x238.jpg 300w, https:\/\/heatpumpingtechnologies.org\/content\/uploads\/sites\/75\/2025\/03\/fr006-house-1-400x318.jpg 400w\" sizes=\"auto, (max-width: 539px) 100vw, 539px\" \/><\/figure>\n<\/div>\n\n<div class=\"container container--no-margin\">\n<p class=\"wp-block-paragraph \">The aim of this renovation is to improve the energy label of the flats to reduce the tenants&#8217; energy bills and carbon footprint by 50%, but also to improve comfort through various means, making the district more attractive. The building was constructed in 1963 and had an energy label rated D for energy consumption and F for greenhouse gas emissions.<\/p>\n<\/div>\n\n<div class=\"container container--no-margin\">\n<p class=\"wp-block-paragraph \"><strong>Works on the building envelope:<\/strong><\/p>\n<\/div>\n\n<div class=\"container container--no-margin\">\n<p class=\"wp-block-paragraph \">The fa\u00e7ades were rebuilt and insulated from the outside and the windows were replaced. The roofs have been redone. All flats have balconies of almost 4 m\u00b2. The halls have been extended with the construction of an overhang, and the stairwells have been refurbished.<\/p>\n<\/div>\n\n<div class=\"container container--no-margin\">\n<p class=\"wp-block-paragraph \"><strong>Works on Space Heating, DHW, and ventilation:<\/strong><\/p>\n<\/div>\n\n<div class=\"container container--no-margin\">\n<p class=\"wp-block-paragraph \">The collective boiler room for heating and the individual bath heaters for DHW production were eliminated in favor of an individualized solution, and a mechanical ventilation system was created in the flats using a NIBE F730 exhaust air heat pump. This heat pump provides heating and domestic hot water for the dwelling, as well as the mechanical ventilation system, to ensure good air quality for the occupants of the flats.<br>A small VMC network had to be created because the flats had natural ventilation. The radiators were replaced and fitted with thermostatic valves.<br>A current sensor has been installed on the general power supply of each flats. Controlled by the heat pump regulation system, it enables load shedding if necessary.<\/p>\n<\/div>\n\n<div class=\"container container--no-margin\">\n<p class=\"wp-block-paragraph \"><strong>Result of the energy label after energy renovation: A for energy consumption and A for greenhouse gas emissions.<\/strong><\/p>\n<\/div>\n\n<div class=\"container container--no-margin\">\n<p class=\"wp-block-paragraph \"><strong>Lessons learned<\/strong><\/p>\n<\/div>\n\n<div class=\"container container--no-margin\">\n<ul class=\"wp-block-list\">\n<li>Compact all-in-one solution with no oudoor unit, ideal to replace individual SH\/DHW boiler<\/li>\n\n\n\n<li>Simplified installation<\/li>\n<\/ul>\n<\/div><\/div>\n\n\n<div class=\"container container--no-margin\">\n<p class=\"wp-block-paragraph \"><strong>Key facts<\/strong><\/p>\n<\/div>\n\n\n<div class=\"wp-block-group is-layout-constrained wp-block-group-is-layout-constrained\"><div class=\"container container--no-margin\">\n<figure class=\"wp-block-table is-style-stripes\"><table><tbody><tr><td><strong>Building<\/strong><\/td><td><\/td><td><strong>Heat Pump and Source<\/strong><\/td><td><\/td><\/tr><tr><td>Location<\/td><td><em>Flers, France<\/em><\/td><td>Number of HP<\/td><td>112<\/td><\/tr><tr><td>Construction<\/td><td>1963<\/td><td>Installed power<\/td><td>&#8212;<\/td><\/tr><tr><td>Refurbishment<\/td><td><em>yes<\/em><\/td><td>Operation mode<\/td><td><em>monoenergetic<\/em><\/td><\/tr><tr><td>Heat distribution<\/td><td><em>radiators<\/em><\/td><td>Heat source<\/td><td><em>exhaust air<\/em><\/td><\/tr><tr><td>Heated area<\/td><td>112 x 60m\u00b2<\/td><td>Type of system<\/td><td><em>individual flats<\/em><\/td><\/tr><tr><td>No. of apartments<\/td><td>112<\/td><td>Model<\/td><td>NIBE F730<\/td><\/tr><tr><td>level of insulation<\/td><td><em>good<\/em><\/td><td><\/td><td><\/td><\/tr><tr><td><\/td><td><\/td><td><\/td><td><\/td><\/tr><tr><td><strong>Heating sytem<\/strong><\/td><td><\/td><td><strong>Domestic Hot Water<\/strong><\/td><td><\/td><\/tr><tr><td>Total demand (SH, DHW,<br>ventilation)<\/td><td><em>6385 Kwh\/a<\/em><\/td><td>DHW demand<\/td><td><em>see value to the left<\/em><\/td><\/tr><tr><td>Heating<br>temperature<\/td><td><em>55\u00b0C<\/em><\/td><td>Max. temperature<\/td><td><em>60\u00b0C<\/em><\/td><\/tr><tr><td>Additional heating<\/td><td><\/td><td>Circulation system<\/td><td>&#8211;<\/td><\/tr><tr><td><\/td><td><\/td><td>Type<\/td><td><em>accumulation<\/em><\/td><\/tr><tr><td><strong>Other information<\/strong><\/td><td><\/td><td><\/td><td><\/td><\/tr><tr><td>PV installed<\/td><td>&#8211;<\/td><td>SPF<\/td><td><em>3,38<\/em><\/td><\/tr><tr><td>Climate Zone<\/td><td><em>Cfb<\/em><\/td><td>Refrigerant<\/td><td><em>R407c<\/em><\/td><\/tr><tr><td><\/td><td><\/td><td>Storage tank<\/td><td><em>180l<\/em><\/td><\/tr><tr><td><\/td><td><\/td><td><\/td><td><\/td><\/tr><\/tbody><\/table><\/figure>\n<\/div><\/div>\n\n\n<div class=\"container\">\n<figure class=\"wp-block-image size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"843\" height=\"484\" src=\"https:\/\/heatpumpingtechnologies.org\/content\/uploads\/sites\/75\/2025\/03\/fr006-scheme.png\" alt=\"\" class=\"wp-image-2825\" style=\"width:683px;height:auto\" srcset=\"https:\/\/heatpumpingtechnologies.org\/content\/uploads\/sites\/75\/2025\/03\/fr006-scheme.png 843w, https:\/\/heatpumpingtechnologies.org\/content\/uploads\/sites\/75\/2025\/03\/fr006-scheme-300x172.png 300w, https:\/\/heatpumpingtechnologies.org\/content\/uploads\/sites\/75\/2025\/03\/fr006-scheme-768x441.png 768w, https:\/\/heatpumpingtechnologies.org\/content\/uploads\/sites\/75\/2025\/03\/fr006-scheme-400x230.png 400w\" sizes=\"auto, (max-width: 843px) 100vw, 843px\" \/><\/figure>\n<\/div>\n\n<div class=\"container container--no-margin\">\n<p class=\"wp-block-paragraph \"><strong>Description of the technical concept<\/strong><\/p>\n<\/div>\n\n<div class=\"container container--no-margin\">\n<p class=\"wp-block-paragraph \">The exhaust air heat pump NIBE F70 recycles and uses the energy wasted by the mechanical ventilation system by collecting the warm air that is evacuated to the outside by the ventilation system and reusing it to produce heating and domestic hot water for the building.<\/p>\n<\/div>\n\n\n<div class=\"wp-block-group is-layout-constrained wp-block-group-is-layout-constrained\"><div class=\"container container--no-margin\">\n<div class=\"wp-block-buttons is-horizontal is-content-justification-center is-layout-flex wp-container-core-buttons-is-layout-b989473c wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button has-custom-width wp-block-button__width-50 has-custom-font-size is-style-outline has-medium-font-size is-style-outline--1\" style=\"text-transform:none\"><a class=\"wp-block-button__link has-vivid-cyan-blue-color has-white-background-color has-text-color has-background has-text-align-center wp-element-button\" href=\"https:\/\/heatpumpingtechnologies.org\/content\/uploads\/sites\/75\/2025\/03\/fr006fact-sheet-nibe-flersv2.pdf\" style=\"border-radius:5px\"><img loading=\"lazy\" decoding=\"async\" width=\"300\" height=\"84\" class=\"wp-image-2196\" style=\"width: 300px;\" src=\"https:\/\/heatpumpingtechnologies.org\/content\/uploads\/sites\/75\/2024\/02\/fact-sheet-button-pic.png\" alt=\"\" srcset=\"https:\/\/heatpumpingtechnologies.org\/content\/uploads\/sites\/75\/2024\/02\/fact-sheet-button-pic.png 845w, https:\/\/heatpumpingtechnologies.org\/content\/uploads\/sites\/75\/2024\/02\/fact-sheet-button-pic-300x84.png 300w, https:\/\/heatpumpingtechnologies.org\/content\/uploads\/sites\/75\/2024\/02\/fact-sheet-button-pic-768x215.png 768w, https:\/\/heatpumpingtechnologies.org\/content\/uploads\/sites\/75\/2024\/02\/fact-sheet-button-pic-400x112.png 400w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/a><\/div>\n<\/div>\n<\/div>\n\n<div class=\"container container--no-margin\">\n<p class=\"has-text-align-center wp-block-paragraph \">DE012 Heat in the West&nbsp;<\/p>\n<\/div><\/div>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>Exhaust air Heat pump for SH and DHW The replacement of a fossil fuel central heating system with individual exhaust&#8230;<\/p>\n","protected":false},"author":41,"featured_media":0,"menu_order":0,"template":"","filters":[],"markets":[23],"applications":[7,41],"class_list":["post-2822","case_studies","type-case_studies","status-publish","hentry","markets-france","applications-buildings","applications-multi-family-buildings"],"acf":[],"_links":{"self":[{"href":"https:\/\/heatpumpingtechnologies.org\/project62\/wp-json\/wp\/v2\/case_studies\/2822","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/heatpumpingtechnologies.org\/project62\/wp-json\/wp\/v2\/case_studies"}],"about":[{"href":"https:\/\/heatpumpingtechnologies.org\/project62\/wp-json\/wp\/v2\/types\/case_studies"}],"author":[{"embeddable":true,"href":"https:\/\/heatpumpingtechnologies.org\/project62\/wp-json\/wp\/v2\/users\/41"}],"version-history":[{"count":2,"href":"https:\/\/heatpumpingtechnologies.org\/project62\/wp-json\/wp\/v2\/case_studies\/2822\/revisions"}],"predecessor-version":[{"id":2828,"href":"https:\/\/heatpumpingtechnologies.org\/project62\/wp-json\/wp\/v2\/case_studies\/2822\/revisions\/2828"}],"wp:attachment":[{"href":"https:\/\/heatpumpingtechnologies.org\/project62\/wp-json\/wp\/v2\/media?parent=2822"}],"wp:term":[{"taxonomy":"filters","embeddable":true,"href":"https:\/\/heatpumpingtechnologies.org\/project62\/wp-json\/wp\/v2\/filters?post=2822"},{"taxonomy":"markets","embeddable":true,"href":"https:\/\/heatpumpingtechnologies.org\/project62\/wp-json\/wp\/v2\/markets?post=2822"},{"taxonomy":"applications","embeddable":true,"href":"https:\/\/heatpumpingtechnologies.org\/project62\/wp-json\/wp\/v2\/applications?post=2822"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}