{"id":2791,"date":"2025-01-03T13:48:42","date_gmt":"2025-01-03T13:48:42","guid":{"rendered":"https:\/\/heatpumpingtechnologies.org\/annex62\/?page_id=2791"},"modified":"2025-09-12T14:52:08","modified_gmt":"2025-09-12T14:52:08","slug":"it009-via-baldissera-italy","status":"publish","type":"case_studies","link":"https:\/\/heatpumpingtechnologies.org\/project62\/case-studies\/it009-via-baldissera-italy\/","title":{"rendered":"IT009 Via Baldissera, Italy"},"content":{"rendered":"\n<div class=\"wp-block-group is-layout-constrained wp-block-group-is-layout-constrained\">\n<div class=\"wp-block-group is-layout-constrained wp-block-group-is-layout-constrained\"><div class=\"container container--no-margin\">\n<p class=\"wp-block-paragraph \" style=\"font-size:25px\">Heat Pump, 2000l Storage Tank and Thermal Panels<\/p>\n<\/div><\/div>\n\n\n<div class=\"container container--no-margin\">\n<p class=\"wp-block-paragraph \">A combination of different heating and cooling methods significantly lowered the running costs for this 1960s Milanese building.<\/p>\n<\/div>\n\n<div class=\"container\">\n<figure class=\"wp-block-image aligncenter size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"998\" height=\"562\" src=\"https:\/\/heatpumpingtechnologies.org\/content\/uploads\/sites\/75\/2025\/01\/it009-house.jpg\" alt=\"\" class=\"wp-image-2792\" style=\"aspect-ratio:1.6289592760180995;width:548px;height:auto\" srcset=\"https:\/\/heatpumpingtechnologies.org\/content\/uploads\/sites\/75\/2025\/01\/it009-house.jpg 998w, https:\/\/heatpumpingtechnologies.org\/content\/uploads\/sites\/75\/2025\/01\/it009-house-300x169.jpg 300w, https:\/\/heatpumpingtechnologies.org\/content\/uploads\/sites\/75\/2025\/01\/it009-house-768x432.jpg 768w, https:\/\/heatpumpingtechnologies.org\/content\/uploads\/sites\/75\/2025\/01\/it009-house-400x225.jpg 400w\" sizes=\"auto, (max-width: 998px) 100vw, 998px\" \/><\/figure>\n<\/div>\n\n<div class=\"container container--no-margin\">\n<p class=\"wp-block-paragraph \">Located in the centre of Milan, the 1960s building consists of 36 flats covering a total of 4500 m2. The air-conditioning system was based on two old boilers for heating and domestic hot water respectively, a chiller for cooling and distribution with radiators and fancoils.<\/p>\n<\/div>\n\n<div class=\"container container--no-margin\">\n<p class=\"wp-block-paragraph \">Challenge:<\/p>\n<\/div>\n\n<div class=\"container container--no-margin\">\n<p class=\"wp-block-paragraph \">In 2023 the condominium assembly decides to proceed with the energy requalification in order to reduce running costs, by intervening on the existing air-conditioning system.<\/p>\n<\/div>\n\n<div class=\"container container--no-margin\">\n<p class=\"wp-block-paragraph \">The most important cost item to work on is that for Domestic Hot Water (DHW) production.<\/p>\n<\/div>\n\n<div class=\"container container--no-margin\">\n<p class=\"wp-block-paragraph \">The solution chosen to cut down the cost for domestic hot water production is a system based on 1 high-efficiency heat pump with inverter technology and ecological refrigerant R32 Sheen EVO 2.0 combined with a 2000 litre storage tank and thermal solar panels, plus a condensing boiler that acts as a back-up during peak demand.<\/p>\n<\/div>\n\n<div class=\"container container--no-margin\">\n<p class=\"wp-block-paragraph \"><strong>Lessons learned<\/strong><br>The heat pump system combined with storage tank and thermal solar panels has proved to be an excellent solution for improving the building&#8217;s energy efficiency and cut down the costs for domestic hot water production.<\/p>\n<\/div>\n\n\n<div class=\"wp-block-group is-layout-constrained wp-block-group-is-layout-constrained\"><div class=\"container container--no-margin\">\n<p class=\"wp-block-paragraph \"><strong>Key facts<\/strong><\/p>\n<\/div>\n\n\n<div class=\"wp-block-group is-layout-constrained wp-block-group-is-layout-constrained\"><div class=\"container container--no-margin\">\n<figure class=\"wp-block-table is-style-stripes\"><table><tbody><tr><td><strong>Building<\/strong><\/td><td><\/td><td><strong>Heat Pump and Source<\/strong><\/td><td><\/td><\/tr><tr><td>Location<\/td><td><em>Milan, Italy<\/em><\/td><td>Number of HP<\/td><td><em>1<\/em><\/td><\/tr><tr><td>Construction<\/td><td><em>1960<\/em><\/td><td>Installed power<\/td><td><em>93 kW<\/em><\/td><\/tr><tr><td>Refurbishment<\/td><td><em>2024<\/em><\/td><td>Operation mode<\/td><td><em>hybrid<\/em><\/td><\/tr><tr><td>Heat distribution<\/td><td><em>radiators<\/em>,<em> fancoils<\/em><\/td><td>Heat source<\/td><td><em>ambient air<\/em><\/td><\/tr><tr><td>Heated area<\/td><td><em>4500 m\u00b2<\/em><\/td><td>Type of system<\/td><td><em>Central<\/em><\/td><\/tr><tr><td>No. of apartments<\/td><td><em>36<\/em><\/td><td>Model<\/td><td><em>Sheen EVO 2.0 heat pumps<\/em><\/td><\/tr><tr><td>level of insulation<\/td><td>&#8211;<\/td><td><\/td><td><\/td><\/tr><tr><td><\/td><td><\/td><td><\/td><td><\/td><\/tr><tr><td><strong>Heating sytem<\/strong><\/td><td><\/td><td><strong>Domestic Hot Water<\/strong><\/td><td><\/td><\/tr><tr><td>Heat demand<\/td><td><em>&#8211; kWh \/ (m\u00b2a)<\/em><\/td><td>DHW demand<\/td><td><em>&#8211; kWh \/ (m\u00b2a)<\/em><\/td><\/tr><tr><td>Heating<br>temperature<\/td><td><em>-\u00b0C<\/em><\/td><td>Max. temperature<\/td><td><em>70\u00b0C <\/em><\/td><\/tr><tr><td>Via<\/td><td><em>Gas boiler <\/em><br><em>2 x 195kW<\/em><\/td><td>Circulation system<\/td><td>&#8211;<\/td><\/tr><tr><td><\/td><td><\/td><td>Type<\/td><td><em>centralized system<\/em><\/td><\/tr><tr><td><\/td><td><\/td><td>Additional heating<\/td><td><em>ST panels<\/em><br><em>back-up boiler<\/em><\/td><\/tr><tr><td><strong>Other information<\/strong><\/td><td><\/td><td><\/td><td><\/td><\/tr><tr><td>PV installed<\/td><td><em>yes<\/em><\/td><td>COP<\/td><td><em>&#8211;<\/em><\/td><\/tr><tr><td>Climate Zone<\/td><td><em>Cfa<\/em><\/td><td>Refrigerant<\/td><td><em>R32<\/em><\/td><\/tr><tr><td><\/td><td><\/td><td><\/td><td><\/td><\/tr><tr><td><\/td><td><\/td><td><\/td><td><\/td><\/tr><\/tbody><\/table><\/figure>\n<\/div><\/div>\n\n\n<div class=\"container\">\n<figure class=\"wp-block-image size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"585\" height=\"362\" src=\"https:\/\/heatpumpingtechnologies.org\/content\/uploads\/sites\/75\/2025\/01\/it009-scheme.png\" alt=\"\" class=\"wp-image-2794\" style=\"width:652px;height:auto\" srcset=\"https:\/\/heatpumpingtechnologies.org\/content\/uploads\/sites\/75\/2025\/01\/it009-scheme.png 585w, https:\/\/heatpumpingtechnologies.org\/content\/uploads\/sites\/75\/2025\/01\/it009-scheme-300x186.png 300w, https:\/\/heatpumpingtechnologies.org\/content\/uploads\/sites\/75\/2025\/01\/it009-scheme-400x248.png 400w\" sizes=\"auto, (max-width: 585px) 100vw, 585px\" \/><\/figure>\n<\/div>\n\n<div class=\"container container--no-margin\">\n<p class=\"wp-block-paragraph \"><strong>Description of the technical concept<\/strong><\/p>\n<\/div>\n\n<div class=\"container container--no-margin\">\n<p class=\"wp-block-paragraph \">The central heat pump is sourced by ambient air and is turn connected to a 2000l storage unit. This storage unit is also connected to solar panels on the roof and &#8211; as a back-up &#8211; can be fed by a gas boiler (200kW). It distributes DHW to the 36 apartments in the building. Space Heating is provided by another gas boiler via heat exchangers.<\/p>\n<\/div>\n\n<div class=\"container container--no-margin\">\n<p class=\"wp-block-paragraph \">Cooling is also possible through means of ambient air, a chiller and&nbsp; a storage unit.<\/p>\n<\/div>\n\n\n<div class=\"wp-block-group is-layout-constrained wp-block-group-is-layout-constrained\"><div class=\"container container--no-margin\">\n<div class=\"wp-block-buttons is-horizontal is-content-justification-center is-layout-flex wp-container-core-buttons-is-layout-b989473c wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button has-custom-width wp-block-button__width-50 has-custom-font-size is-style-outline has-medium-font-size is-style-outline--1\" style=\"text-transform:none\"><a class=\"wp-block-button__link has-vivid-cyan-blue-color has-white-background-color has-text-color has-background has-text-align-center wp-element-button\" href=\"https:\/\/heatpumpingtechnologies.org\/content\/uploads\/sites\/75\/2025\/01\/it009fact-sheet-via-baldissera.pdf\" style=\"border-radius:5px\" target=\"_blank\" rel=\"noreferrer noopener\"><img loading=\"lazy\" decoding=\"async\" width=\"300\" height=\"84\" class=\"wp-image-2196\" style=\"width: 300px;\" src=\"https:\/\/heatpumpingtechnologies.org\/content\/uploads\/sites\/75\/2024\/02\/fact-sheet-button-pic.png\" alt=\"\" srcset=\"https:\/\/heatpumpingtechnologies.org\/content\/uploads\/sites\/75\/2024\/02\/fact-sheet-button-pic.png 845w, https:\/\/heatpumpingtechnologies.org\/content\/uploads\/sites\/75\/2024\/02\/fact-sheet-button-pic-300x84.png 300w, https:\/\/heatpumpingtechnologies.org\/content\/uploads\/sites\/75\/2024\/02\/fact-sheet-button-pic-768x215.png 768w, https:\/\/heatpumpingtechnologies.org\/content\/uploads\/sites\/75\/2024\/02\/fact-sheet-button-pic-400x112.png 400w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/a><\/div>\n<\/div>\n<\/div>\n\n<div class=\"container container--no-margin\">\n<p class=\"has-text-align-center wp-block-paragraph \">IT009 Via Baldissera\u00a0<\/p>\n<\/div><\/div>\n<\/div>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>Heat Pump, 2000l Storage Tank and Thermal Panels A combination of different heating and cooling methods significantly lowered the running&#8230;<\/p>\n","protected":false},"author":41,"featured_media":0,"menu_order":0,"template":"","filters":[],"markets":[25],"applications":[7,41],"class_list":["post-2791","case_studies","type-case_studies","status-publish","hentry","markets-italy","applications-buildings","applications-multi-family-buildings"],"acf":[],"_links":{"self":[{"href":"https:\/\/heatpumpingtechnologies.org\/project62\/wp-json\/wp\/v2\/case_studies\/2791","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/heatpumpingtechnologies.org\/project62\/wp-json\/wp\/v2\/case_studies"}],"about":[{"href":"https:\/\/heatpumpingtechnologies.org\/project62\/wp-json\/wp\/v2\/types\/case_studies"}],"author":[{"embeddable":true,"href":"https:\/\/heatpumpingtechnologies.org\/project62\/wp-json\/wp\/v2\/users\/41"}],"version-history":[{"count":1,"href":"https:\/\/heatpumpingtechnologies.org\/project62\/wp-json\/wp\/v2\/case_studies\/2791\/revisions"}],"predecessor-version":[{"id":2796,"href":"https:\/\/heatpumpingtechnologies.org\/project62\/wp-json\/wp\/v2\/case_studies\/2791\/revisions\/2796"}],"wp:attachment":[{"href":"https:\/\/heatpumpingtechnologies.org\/project62\/wp-json\/wp\/v2\/media?parent=2791"}],"wp:term":[{"taxonomy":"filters","embeddable":true,"href":"https:\/\/heatpumpingtechnologies.org\/project62\/wp-json\/wp\/v2\/filters?post=2791"},{"taxonomy":"markets","embeddable":true,"href":"https:\/\/heatpumpingtechnologies.org\/project62\/wp-json\/wp\/v2\/markets?post=2791"},{"taxonomy":"applications","embeddable":true,"href":"https:\/\/heatpumpingtechnologies.org\/project62\/wp-json\/wp\/v2\/applications?post=2791"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}