{"id":1381,"date":"2025-01-10T14:29:00","date_gmt":"2025-01-10T14:29:00","guid":{"rendered":"https:\/\/heatpumpingtechnologies.org\/annex61\/?p=1381"},"modified":"2025-05-02T12:24:47","modified_gmt":"2025-05-02T12:24:47","slug":"annex-61-conference-papers-published","status":"publish","type":"post","link":"https:\/\/heatpumpingtechnologies.org\/project61\/annex-61-conference-papers-published\/","title":{"rendered":"Annex 61 Conference papers published"},"content":{"rendered":"<div class=\"container container--no-margin classic-editor\">The conference papers of Annex 61 participants summitted to the Eurosun 2024, which took place in August 2024 and the Bausim 2024 which took place in September 2024 have been meanwhile published.<br \/>\nAt the Eurosun 2024 the Annex 61 publication of the Univ. of Innsbruck has been published in the &#8220;Solar Energy Advances&#8221; Journal&#8217;s Special Issue. It deals with a simplied modelling of characteristic load curves for districts, which is validated with data from the Campagne district in Austria and applied to evaluate different measures to address the winter energy and power gap.<br \/>\nAt the Bausim 2024 different papers on simulation activities within the Annex 61 have been published. Interim results of different Annex 61 simulations projects are compiled in joint Annex 61 paper by AT, CH and DE participants. Results of the simulations of TH N\u00fcrnberg of a model multi-family house retrofit concept was additionally presented as poster. A further paper of the TH N\u00fcrnberg focuses on the influence of different weather forecast on predictive control. Furthermore, a publication of the Univ. of Innsbruck and the Univ. of Thessaly deals with decentral split air-to-air heat pumps, also denoted as air-conditioning units, testing and refrigerant cycle simulation. In the test, performed for steady state and dynamic conditions, the COP of the units was in the range fo 1.8 to 4.9 and the maximum measured heat capacity was with 2.5 kW closed to the nominal value of 2.7 kW.\u00a0 The measured reduction due to the defrost cycle was up to 14% in heating capacity and 16% in COP.<\/p>\n<p>Further publication have been submitted to upcoming conferences REHVA Clima 2025 in June in Milan, the CISBAT 2025 in Sept. 2025 in Lausanne, the Smart Energy conference in Sept. 2025 in Copenhague and the European Heat Pump Summit in N\u00fcrnberg in end of October 2025.<br \/>\nThe publicly available papers are found as link under <a href=\"https:\/\/heatpumpingtechnologies.org\/annex61\/publications\">publications<\/a>.<\/div>\n","protected":false},"excerpt":{"rendered":"<p>The conference papers of Annex 61 participants summitted to the Eurosun 2024, which took place in August 2024 and the&#8230;<\/p>\n","protected":false},"author":9,"featured_media":1400,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_relevanssi_hide_post":"","_relevanssi_hide_content":"","_relevanssi_pin_for_all":"","_relevanssi_pin_keywords":"","_relevanssi_unpin_keywords":"","_relevanssi_related_keywords":"","_relevanssi_related_include_ids":"","_relevanssi_related_exclude_ids":"","_relevanssi_related_no_append":"","_relevanssi_related_not_related":"","_relevanssi_related_posts":"","_relevanssi_noindex_reason":"","footnotes":""},"categories":[1],"tags":[],"markets":[],"class_list":["post-1381","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-uncategorized"],"acf":[],"_links":{"self":[{"href":"https:\/\/heatpumpingtechnologies.org\/project61\/wp-json\/wp\/v2\/posts\/1381","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/heatpumpingtechnologies.org\/project61\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/heatpumpingtechnologies.org\/project61\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/heatpumpingtechnologies.org\/project61\/wp-json\/wp\/v2\/users\/9"}],"replies":[{"embeddable":true,"href":"https:\/\/heatpumpingtechnologies.org\/project61\/wp-json\/wp\/v2\/comments?post=1381"}],"version-history":[{"count":4,"href":"https:\/\/heatpumpingtechnologies.org\/project61\/wp-json\/wp\/v2\/posts\/1381\/revisions"}],"predecessor-version":[{"id":1417,"href":"https:\/\/heatpumpingtechnologies.org\/project61\/wp-json\/wp\/v2\/posts\/1381\/revisions\/1417"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/heatpumpingtechnologies.org\/project61\/wp-json\/wp\/v2\/media\/1400"}],"wp:attachment":[{"href":"https:\/\/heatpumpingtechnologies.org\/project61\/wp-json\/wp\/v2\/media?parent=1381"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/heatpumpingtechnologies.org\/project61\/wp-json\/wp\/v2\/categories?post=1381"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/heatpumpingtechnologies.org\/project61\/wp-json\/wp\/v2\/tags?post=1381"},{"taxonomy":"markets","embeddable":true,"href":"https:\/\/heatpumpingtechnologies.org\/project61\/wp-json\/wp\/v2\/markets?post=1381"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}