{"id":1152,"date":"2022-02-18T10:58:36","date_gmt":"2022-02-18T10:58:36","guid":{"rendered":"https:\/\/heatpumpingtechnologies.org\/annex50\/?page_id=1152"},"modified":"2023-12-15T11:52:27","modified_gmt":"2023-12-15T11:52:27","slug":"solution-2-1","status":"publish","type":"page","link":"https:\/\/heatpumpingtechnologies.org\/annex50\/solution-2-1\/","title":{"rendered":"2.1 Combination Central &#8211; Decentral"},"content":{"rendered":"<div class=\"container container--no-margin\">\n<p class=\"has-black-color has-text-color has-medium-font-size wp-block-paragraph \"><strong>ONE MODE &#8211; CENTRAL, SECOND &#8211; DECENTRAL<\/strong><\/p>\n<\/div>\n\n<div class=\"container\">\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-9d6595d7 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:33.33%\"><div class=\"container\">\n<figure class=\"wp-block-image alignleft size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"299\" height=\"270\" src=\"https:\/\/heatpumpingtechnologies.org\/content\/uploads\/sites\/56\/2022\/02\/21-1.png\" alt=\"\" class=\"wp-image-1155\" style=\"width:224px;height:201px\"\/><\/figure>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:66.66%\"><div class=\"container\">\n<figure class=\"wp-block-image aligncenter size-large is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"361\" src=\"https:\/\/heatpumpingtechnologies.org\/content\/uploads\/sites\/56\/2022\/02\/21ubersicht-1-1024x361.png\" alt=\"\" class=\"wp-image-1157\" style=\"width:587px;height:206px\" srcset=\"https:\/\/heatpumpingtechnologies.org\/content\/uploads\/sites\/56\/2022\/02\/21ubersicht-1-1024x361.png 1024w, https:\/\/heatpumpingtechnologies.org\/content\/uploads\/sites\/56\/2022\/02\/21ubersicht-1-300x106.png 300w, https:\/\/heatpumpingtechnologies.org\/content\/uploads\/sites\/56\/2022\/02\/21ubersicht-1-768x271.png 768w, https:\/\/heatpumpingtechnologies.org\/content\/uploads\/sites\/56\/2022\/02\/21ubersicht-1-400x141.png 400w, https:\/\/heatpumpingtechnologies.org\/content\/uploads\/sites\/56\/2022\/02\/21ubersicht-1.png 1395w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n<\/div><\/div>\n<\/div>\n<\/div>\n\n<div class=\"container\">\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-9d6595d7 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-vertically-aligned-top is-layout-flow wp-block-column-is-layout-flow\"><div class=\"container container--no-margin\">\n<h4 class=\"wp-block-heading\"><strong>Main characteristic of the concept<\/strong><\/h4>\n<\/div>\n\n<div class=\"container container--no-margin\">\n<p class=\"wp-block-paragraph \">One central heat pump system for one mode (for example space heating) and decentral heat pumps for the second mode (for example DHW). Also possible with a central heat pump if lower temperature level available or decentral heat pumps for a higher temperature level.<\/p>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\"><div class=\"container container--no-margin\">\n<h4 class=\"wp-block-heading\"><strong>Heat distribution and temperatures levels<\/strong><\/h4>\n<\/div>\n\n<div class=\"container container--no-margin\">\n<p class=\"wp-block-paragraph \">In this solution the higher temperature level for the DHW is provided by an additional (small capacity) heat pumps in each apartment. The central heat pump for the space heating (or for delivering the heat source for decentral heat pumps) can be optimized for lower temperature levels.<\/p>\n<\/div><\/div>\n<\/div>\n<\/div>\n\n<div class=\"container\">\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-9d6595d7 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\"><div class=\"container container--no-margin\">\n<h4 class=\"wp-block-heading\"><strong>Size of building, number of apartments<\/strong><\/h4>\n<\/div>\n\n<div class=\"container container--no-margin\">\n<p class=\"wp-block-paragraph \">This solution is suitable for all sizes of buildings with the preference for average and larger ones.<\/p>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\"><div class=\"container container--no-margin\">\n<h4 class=\"wp-block-heading\"><strong>DHW and storage characteristic<\/strong><\/h4>\n<\/div>\n\n<div class=\"container container--no-margin\">\n<p class=\"wp-block-paragraph \">DHW is produced separately in each apartment with a decentral heat pump. The heat distribution losses are significantly smaller than in case of a central solution. The size of DHW storages can by reduced. This solution allows an easier solution for the legionella issue.&nbsp;<\/p>\n<\/div><\/div>\n<\/div>\n<\/div>\n\n<div class=\"container\">\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-9d6595d7 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\"><div class=\"container container--no-margin\">\n<h4 class=\"wp-block-heading\"><strong>Energy standard, insulation level&nbsp;<\/strong><\/h4>\n<\/div>\n\n<div class=\"container container--no-margin\">\n<p class=\"wp-block-paragraph \">Depending on the final realisation of this solution, this concept can be used for buildings with any energy standard. The solution with a low temperature level for the heating and booster heat pumps for DHW is rather for buildings with a high energetical standard.&nbsp;&nbsp;&nbsp;<\/p>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\"><div class=\"container container--no-margin\">\n<h4 class=\"wp-block-heading\"><strong>Complexity of installation<\/strong><\/h4>\n<\/div>\n\n<div class=\"container container--no-margin\">\n<p class=\"wp-block-paragraph \">Rather a complex solution, which requires higher number of heat pumps. Possibility for a convenient usage of outside air as a main source of the central heat pump using roof top heat exchangers (evaporators).<\/p>\n<\/div><\/div>\n<\/div>\n<\/div>\n\n<div class=\"container\">\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-9d6595d7 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\"><div class=\"container container--no-margin\">\n<h4 class=\"wp-block-heading\"><strong>Heat Sources<\/strong><\/h4>\n<\/div>\n\n<div class=\"container container--no-margin\">\n<p class=\"wp-block-paragraph \">For the main heat pump, all types of heat sources are possible. For the decentral heat pumps &#8211; exhaust air or the or the return water pipe of the space heating may be the heat source.<\/p>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\"><div class=\"container container--no-margin\">\n<h4 class=\"wp-block-heading\"><strong>Specific issues of the concept<\/strong><\/h4>\n<\/div>\n\n<div class=\"container container--no-margin\">\n<p class=\"wp-block-paragraph \">May be convenient as a solution for high-rise buildings. Using different temperature levels. Boosting of temperature possible.<\/p>\n<\/div><\/div>\n<\/div>\n<\/div>\n\n<div class=\"container\">\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-9d6595d7 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\"><div class=\"container container--no-margin\">\n<p class=\"has-black-color has-light-green-cyan-background-color has-text-color has-background wp-block-paragraph \" style=\"font-size:18px\"><strong>Positive aspects<\/strong><\/p>\n<\/div>\n\n<div class=\"container container--no-margin\">\n<ul class=\"wp-block-list\">\n<li>Individual DHW<\/li>\n\n\n\n<li>High efficiency possible<\/li>\n\n\n\n<li>Smaller distribution losses<\/li>\n<\/ul>\n<\/div>\n\n<div class=\"container container--no-margin\">\n<p class=\"wp-block-paragraph \"><\/p>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\"><div class=\"container container--no-margin\">\n<p class=\"has-black-color has-pale-pink-background-color has-text-color has-background wp-block-paragraph \" style=\"font-size:18px\"><strong>Negative aspects<\/strong><\/p>\n<\/div>\n\n<div class=\"container container--no-margin\">\n<ul class=\"wp-block-list\">\n<li>Higher investment<\/li>\n<\/ul>\n<\/div>\n\n<div class=\"container container--no-margin\">\n<p class=\"wp-block-paragraph \"><\/p>\n<\/div><\/div>\n<\/div>\n<\/div>\n\n<div class=\"container container--no-margin\">\n<div class=\"wp-block-buttons is-layout-flex wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button\"><a class=\"wp-block-button__link has-white-color has-text-color has-background wp-element-button\" href=\"https:\/\/heatpumpingtechnologies.org\/annex50\/case-studies\/hot-ice-weiz\/\" style=\"background-color:#4e81bd\"><strong>See Example<\/strong><\/a><\/div>\n<\/div>\n<\/div>\n\n<div class=\"container container--no-margin\">\n<hr class=\"wp-block-separator has-css-opacity is-style-wide\"\/>\n<\/div>\n\n<div class=\"container container--no-margin\">\n<div class=\"wp-block-buttons is-layout-flex wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button\"><a class=\"wp-block-button__link has-white-color has-text-color has-background wp-element-button\" href=\"https:\/\/heatpumpingtechnologies.org\/annex50\/each-solution-description\/\" style=\"background-color:#4e81bd\"><strong>Description of Each Solution<\/strong><\/a><\/div>\n<\/div>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>ONE MODE &#8211; CENTRAL, SECOND &#8211; DECENTRAL Main characteristic of the concept One central heat pump system for one mode&#8230;<\/p>\n","protected":false},"author":7,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_acf_changed":false,"_relevanssi_hide_post":"","_relevanssi_hide_content":"","_relevanssi_pin_for_all":"","_relevanssi_pin_keywords":"","_relevanssi_unpin_keywords":"","_relevanssi_related_keywords":"","_relevanssi_related_include_ids":"","_relevanssi_related_exclude_ids":"","_relevanssi_related_no_append":"","_relevanssi_related_not_related":"","_relevanssi_related_posts":"","_relevanssi_noindex_reason":"","footnotes":""},"class_list":["post-1152","page","type-page","status-publish","hentry"],"acf":[],"_links":{"self":[{"href":"https:\/\/heatpumpingtechnologies.org\/annex50\/wp-json\/wp\/v2\/pages\/1152","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/heatpumpingtechnologies.org\/annex50\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/heatpumpingtechnologies.org\/annex50\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/heatpumpingtechnologies.org\/annex50\/wp-json\/wp\/v2\/users\/7"}],"replies":[{"embeddable":true,"href":"https:\/\/heatpumpingtechnologies.org\/annex50\/wp-json\/wp\/v2\/comments?post=1152"}],"version-history":[{"count":5,"href":"https:\/\/heatpumpingtechnologies.org\/annex50\/wp-json\/wp\/v2\/pages\/1152\/revisions"}],"predecessor-version":[{"id":1606,"href":"https:\/\/heatpumpingtechnologies.org\/annex50\/wp-json\/wp\/v2\/pages\/1152\/revisions\/1606"}],"wp:attachment":[{"href":"https:\/\/heatpumpingtechnologies.org\/annex50\/wp-json\/wp\/v2\/media?parent=1152"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}