{"id":1144,"date":"2022-02-18T10:58:06","date_gmt":"2022-02-18T10:58:06","guid":{"rendered":"https:\/\/heatpumpingtechnologies.org\/annex50\/?page_id=1144"},"modified":"2022-04-07T12:40:42","modified_gmt":"2022-04-07T12:40:42","slug":"solution-1-5","status":"publish","type":"page","link":"https:\/\/heatpumpingtechnologies.org\/annex50\/solution-1-5\/","title":{"rendered":"1.5 Centralized Heat Pump for the Whole Building"},"content":{"rendered":"<div class=\"container container--no-margin\">\n<p class=\"has-black-color has-text-color has-medium-font-size wp-block-paragraph \"><strong><strong>ONE HYBRID HEAT PUMP FOR ALL<\/strong><\/strong><\/p>\n<\/div>\n\n<div class=\"container\">\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-9d6595d7 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:33.33%\"><div class=\"container\">\n<div class=\"wp-block-image\"><figure class=\"alignleft size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"299\" height=\"270\" src=\"https:\/\/heatpumpingtechnologies.org\/content\/uploads\/sites\/56\/2022\/02\/15-1.png\" alt=\"\" class=\"wp-image-1147\" \/><\/figure><\/div>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:66.66%\"><div class=\"container\">\n<div class=\"wp-block-image\"><figure class=\"aligncenter size-large is-resized\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/heatpumpingtechnologies.org\/content\/uploads\/sites\/56\/2022\/02\/15ubersicht-1-1024x361.png\" alt=\"\" class=\"wp-image-1168\" width=\"632\" height=\"222\" srcset=\"https:\/\/heatpumpingtechnologies.org\/content\/uploads\/sites\/56\/2022\/02\/15ubersicht-1-1024x361.png 1024w, https:\/\/heatpumpingtechnologies.org\/content\/uploads\/sites\/56\/2022\/02\/15ubersicht-1-300x106.png 300w, https:\/\/heatpumpingtechnologies.org\/content\/uploads\/sites\/56\/2022\/02\/15ubersicht-1-768x271.png 768w, https:\/\/heatpumpingtechnologies.org\/content\/uploads\/sites\/56\/2022\/02\/15ubersicht-1-400x141.png 400w, https:\/\/heatpumpingtechnologies.org\/content\/uploads\/sites\/56\/2022\/02\/15ubersicht-1.png 1395w\" sizes=\"auto, (max-width: 632px) 100vw, 632px\" \/><\/figure><\/div>\n<\/div><\/div>\n<\/div>\n<\/div>\n\n<div class=\"container\">\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-9d6595d7 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-vertically-aligned-top is-layout-flow wp-block-column-is-layout-flow\"><div class=\"container container--no-margin\">\n<h4 class=\"wp-block-heading\"><strong>Main characteristic of the concept<\/strong><\/h4>\n<\/div>\n\n<div class=\"container container--no-margin\">\n<p class=\"wp-block-paragraph \">One hybrid heat pump system for space heating and DHW for the whole building.<\/p>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\"><div class=\"container container--no-margin\">\n<h4 class=\"wp-block-heading\"><strong>Heat distribution and temperatures levels<\/strong><\/h4>\n<\/div>\n\n<div class=\"container container--no-margin\">\n<p class=\"wp-block-paragraph \">Hybrid systems have several possibilities of separating space heating and DHW production. In most cases the heat pump delivers space heating during spring and autumn and will be assisted by the boiler during low outside temperatures in the winter. The better the insulation, the higher the contribution of the heat pump to the space heating demand.<\/p>\n<\/div><\/div>\n<\/div>\n<\/div>\n\n<div class=\"container\">\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-9d6595d7 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\"><div class=\"container container--no-margin\">\n<h4 class=\"wp-block-heading\"><strong>Size of building, number of apartments<\/strong><\/h4>\n<\/div>\n\n<div class=\"container container--no-margin\">\n<p class=\"wp-block-paragraph \">This solution is suitable for all sizes of buildings with the preference for larger buildings. Hybrid solutions may be useful if the installation of a heat pump with a large capacity is not possible. The limitation factors may be such as an insufficient heat source, particularly high supply temperature or a limitation of grid connection. In some cases, this solution allows for installation of a smaller heat pump as an add-on for existing boiler.<\/p>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\"><div class=\"container container--no-margin\">\n<h4 class=\"wp-block-heading\"><strong>DHW and storage characteristic<\/strong><\/h4>\n<\/div>\n\n<div class=\"container container--no-margin\">\n<p class=\"wp-block-paragraph \">DHW can be pre-heated by the heat pump and finally heated to the desired temperature by the fossil part of the unit. This solution allows for an easier solving of the legionella issue.<\/p>\n<\/div><\/div>\n<\/div>\n<\/div>\n\n<div class=\"container\">\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-9d6595d7 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\"><div class=\"container container--no-margin\">\n<h4 class=\"wp-block-heading\"><strong>Energy standard, insulation level&nbsp;<\/strong><\/h4>\n<\/div>\n\n<div class=\"container container--no-margin\">\n<p class=\"wp-block-paragraph \">This concept can be used for buildings with a high, as well as a low level of insulation. More applicable for older, not refurbished buildings with a higher heating energy demand. This solution is generally not to be recommend for new buildings due to use of fossil energy sources.<\/p>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\"><div class=\"container container--no-margin\">\n<h4 class=\"wp-block-heading\"><strong>Complexity of installation<\/strong><\/h4>\n<\/div>\n\n<div class=\"container container--no-margin\">\n<p class=\"wp-block-paragraph \">In case of an add-on heat pump, the existing system (boiler) and the added heat pump must be connected and controlled together. The technical room must be large enough to install the heat pump and a storage tank close to the existing boiler.<\/p>\n<\/div><\/div>\n<\/div>\n<\/div>\n\n<div class=\"container\">\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-9d6595d7 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\"><div class=\"container container--no-margin\">\n<h4 class=\"wp-block-heading\"><strong>Heat Sources<\/strong><\/h4>\n<\/div>\n\n<div class=\"container container--no-margin\">\n<p class=\"wp-block-paragraph \">Hybrid heat pumps use commonly outside air as a heat source. Generally, all heat sources are possible.<\/p>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\"><div class=\"container container--no-margin\">\n<h4 class=\"wp-block-heading\"><strong>Specific issues of the concept<\/strong><\/h4>\n<\/div>\n\n<div class=\"container container--no-margin\">\n<p class=\"wp-block-paragraph \">The old heat generators may be replaced during retrofitting without changing the distribution system. The global performance of the system is aligned with the share of heat produced by the heat pump. Easy avoiding of legionella through achievement high DHW temperatures with the use of a fossil boiler.\u00a0<\/p>\n<\/div><\/div>\n<\/div>\n<\/div>\n\n<div class=\"container\">\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-9d6595d7 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\"><div class=\"container container--no-margin\">\n<p class=\"has-black-color has-light-green-cyan-background-color has-text-color has-background wp-block-paragraph \" style=\"font-size:18px\"><strong>Positive aspects<\/strong><\/p>\n<\/div>\n\n<div class=\"container container--no-margin\">\n<ul class=\"wp-block-list\"><li>Smaller heat pump capacity<\/li><li>Flexible: meets every grade of insulation<\/li><li>Easy Legionella prevention<\/li><\/ul>\n<\/div>\n\n<div class=\"container container--no-margin\">\n<p class=\"wp-block-paragraph \"><\/p>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\"><div class=\"container container--no-margin\">\n<p class=\"has-black-color has-pale-pink-background-color has-text-color has-background wp-block-paragraph \" style=\"font-size:18px\"><strong>Negative aspects<\/strong><\/p>\n<\/div>\n\n<div class=\"container container--no-margin\">\n<ul class=\"wp-block-list\"><li>High distribution losses<\/li><li>Partial use of fossil fuel<\/li><\/ul>\n<\/div>\n\n<div class=\"container container--no-margin\">\n<p class=\"wp-block-paragraph \"><\/p>\n<\/div><\/div>\n<\/div>\n<\/div>\n\n<div class=\"container container--no-margin\">\n<div class=\"wp-block-buttons is-layout-flex wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button\"><a class=\"wp-block-button__link has-white-color has-text-color has-background\" href=\"https:\/\/heatpumpingtechnologies.org\/annex50\/case-studies\/hot-ice-weiz\/\" style=\"background-color:#4e81bd\"><strong>See Example<\/strong><\/a><\/div>\n<\/div>\n<\/div>\n\n<div class=\"container container--no-margin\">\n<hr class=\"wp-block-separator is-style-wide\" \/>\n<\/div>\n\n<div class=\"container container--no-margin\">\n<div class=\"wp-block-buttons is-layout-flex wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button\"><a class=\"wp-block-button__link has-white-color has-text-color has-background\" href=\"https:\/\/heatpumpingtechnologies.org\/annex50\/each-solution-description\/\" style=\"background-color:#4e81bd\"><strong>Description of Each Solution<\/strong><\/a><\/div>\n<\/div>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>ONE HYBRID HEAT PUMP FOR ALL Main characteristic of the concept One hybrid heat pump system for space heating and&#8230;<\/p>\n","protected":false},"author":7,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_acf_changed":false,"_relevanssi_hide_post":"","_relevanssi_hide_content":"","_relevanssi_pin_for_all":"","_relevanssi_pin_keywords":"","_relevanssi_unpin_keywords":"","_relevanssi_related_keywords":"","_relevanssi_related_include_ids":"","_relevanssi_related_exclude_ids":"","_relevanssi_related_no_append":"","_relevanssi_related_not_related":"","_relevanssi_related_posts":"","_relevanssi_noindex_reason":"","footnotes":""},"class_list":["post-1144","page","type-page","status-publish","hentry"],"acf":[],"_links":{"self":[{"href":"https:\/\/heatpumpingtechnologies.org\/annex50\/wp-json\/wp\/v2\/pages\/1144","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/heatpumpingtechnologies.org\/annex50\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/heatpumpingtechnologies.org\/annex50\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/heatpumpingtechnologies.org\/annex50\/wp-json\/wp\/v2\/users\/7"}],"replies":[{"embeddable":true,"href":"https:\/\/heatpumpingtechnologies.org\/annex50\/wp-json\/wp\/v2\/comments?post=1144"}],"version-history":[{"count":4,"href":"https:\/\/heatpumpingtechnologies.org\/annex50\/wp-json\/wp\/v2\/pages\/1144\/revisions"}],"predecessor-version":[{"id":1487,"href":"https:\/\/heatpumpingtechnologies.org\/annex50\/wp-json\/wp\/v2\/pages\/1144\/revisions\/1487"}],"wp:attachment":[{"href":"https:\/\/heatpumpingtechnologies.org\/annex50\/wp-json\/wp\/v2\/media?parent=1144"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}